No. 51957
GM-P421U
GM-P420UG
41
Item
Test equipment
Test points
Ad justment
locations
Ad justment procedure
RGB offset
(480i)
adjustment
Oscilloscope
NT SC (480i)
Video signal
generator
(Ramp pattern)
CH01
WE04
(R cut off)
WE06
(B cut off)
1. Input the 480i video signal ramp pattern to the COMPONENT
terminal.
2. Change the value in the
<
SERVICE MENU
>
CH01 from “0”
to “2” to enter the tes t mode for RGB balance.
3. Adjust the values in the
<
SERVICE MENU
>
WE04 (R cut
off) and WE06 (B c ut off) so that the 3 lines on the left part of
the PDP s creen are aligned. Keep the WE05 (G cut off) intact.
4. Return the value in the
<
SERVICE MENU
>
CH01 from “2” to
“0”.
RGB offset
(1080i)
adjustment
Oscilloscope
Video signal
generator
(1080i Ramp
pattern)
CH01
WG04
(R cut off)
WG06
(B cut off)
1. Input the 1080i video signal ramp pattern to the COMPONENT
terminal.
2. Change the value in the
<
SERVICE MENU
>
CH01 from “0”
to “2” to enter the tes t mode for RGB balance.
3. Adjust the values in the
<
SERVICE MENU
>
WG04 (R c ut
off) and WG06 (B cut off) so that the 3 lines on the left part of
the PDP s creen are aligned. Keep the WG05 (G cut off) intac t.
4. Return the value in the
<
SERVICE MENU
>
CH01 from “2” to
“0”.
(RAMP pattern)
Align the 3 lines on the left part.
(RAMP pattern)
Align the 3 lines on the left part.