JVA ELECTRIC FENCE SYSTEMS
34
Function
Description
Arm/Disarm
[User PIN][#]
Silence an alarm (Single zone system only)
[User PIN][#]
Start Programming the Z series energizer
[Installer PIN][*] [0] [#]
Start Programming the Keypad
[Installer PIN][*] [0] [1] [#]
Exit Programming (any mode)
[*] [#]
Change a User PIN, 4 Digits
[User PIN][*]0[#][New PIN]#
Change the Installer PIN, 5 Digits
[0] [0] [New Installer PIN][#] Note 1
Arm All Zones (Multi-zone groups)
[User PIN][*][1][0][#]
Arm Zone 1 (Master)
[User PIN][*][1][1][#]
Arm Zone x, where x is any zone number up to 15
[User PIN][*][1][x][#]
Disarm All Zones
[User PIN][*][2][0][#]
Disarm Zone 1 or Master
[User PIN][*][2][1][#]
Disarm Zone x, where x is any zone number up
to 15
[User PIN][*][2][x][#]
Switch to low power mode (all zones)
[User PIN][*][4][1][#]
Switch to high power mode (all zones)
[User PIN][*][4][2][#]
Arm Gate circuits only
[User PIN][*][4][#]
To change the Keypad Messages to English
[*][3][1][#]
To change the Keypad Messages to Spanish
[*][3][2][#] (not well supported yet)
Keypad Audible Feedback On/Off
[*] [5] [1] [#]
Keypad alarm beeper (Chime) On/Off
[*] [5] [3] [#]
Keypad Error Tones On/Off
[*] [5] [4] [#]
Backlight mode On/On with keys/Off
[*] [8] [#]
Display Keypad Model
[*] [9] [#]
Re-analyse the group
[*][6][8][#]
Reset and Display firmware version number
[User PIN][*][6][8][#]
Reset and return to factory defaults
[Installer PIN][*] [6] [8] [#] Note 5
Power Boost
[*] [9] [9] [#]
Siren test
[*] [6] [3] [#]
Battery test
[*] [6] [4] [#]
Clear Alarm memory
[*] [1] [#]
Notes
:
1. Operates while in programming mode only.
JV
A Z114 L
CD K
eypad F
ea
tur
es
8.5 Summary of LCD Keypad Functions