6.1 Power Options
The Z114 has 2 sources of power, 16VAC and 12VDC (Battery). If using solar power
and an external battery, connect the battery to the battery leads, not the 16Vac input.
A 24Vdc 2.5A supply can be used in place of the 16Vac supply. The correct connection
is +24V to the mid AC pin, GND to the left AC pin. Due to the stored energy in a
24Vdc plug-pack, an AC Fail may take up to 5 minutes to be reported.
NOTE
: Use only rechargeable batteries.
6.2 Status Codes
Status Light
Number of Flashes
Interpretation
Corrective Action
1
Tamper detected
Fit the energizer lid or link J3
2
Mains supply fail
Restore mains power
3
Low battery, bad battery Charge or replace battery
4
PCB service fault
Seek advice from your installer or
distributor
Status Codes
If a minor error occurs, it will self-clear if the error condition is removed. If the
mains fail or the battery runs low, it will not disarm the energizer. However, without
mains power, the battery will eventually be depleted and the energizer will attempt
to maintain operation by entering Low Power mode after 4 warning beeps. If the
battery charge continues to fall, the energizer will eventually stop. Once mains
power has been restored and the battery has recovered, the energizer will rearm
itself automatically after 4 warning beeps. A PCB fault will disarm the energizer. If an
error disarms the energizer, the fence alarm will be activated.
If an error has momentarily caused the energizer to stop pulsing, this can be
corrected by disarming and rearming the unit. Should the error recur return the unit
for service.