5. INSTALLATION
JVA recommends installation by qualified technicians.
5.1 Installation Steps
1. Read the entire manual first!
2. Design and build the fence. (Beyond the scope of this manual.) Ask your
distributor for help if required.
3. Decide where the JVA Z114 is to be mounted. If on an external wall it should be
housed within a waterproof equipment box and definitely not in direct sunlight.
4. Remove the JVA Z114 PCB chassis from the housing by removing the 2 screws.
5. Mount the housing by using 4 screws through the rear of the box.
6. Replace the PCB chassis.
7. If using a keypad, remove the rear housing of the keypad and fix it to the wall.
8. Wire the low voltage cables to the PCB terminals*. (See Section 5.2)
9. Wire the high voltage cable to the PCB terminals*. (See Section 5.2)
10. If earth monitoring is not going to be used on the fence, connect a bridge wire
from earth out to earth return.
11. Ensure that the key switch is off.
12. Fit the battery leads to the battery. The Status Light should blink twice repetitively
to show mains fail, unless J3 is fitted.
13. Mount the 230 – 16V transformer and connect the 16V side to the Z114 16V
input terminals. (AC is not polarity sensitive.) Do not connect a live or neutral to
the earth terminal.
14. Replace the front cover.
15. Turn AC power on.
16. Arm and disarm the energizer via the keyswitch or keypad, if fitted. The Status
Light should stop blinking.
17. Arm the unit.
18. Check to ensure that a short anywhere on the fence triggers the alarm.
19. Ensure that the user understands how to change the user code (PIN) and is in
possession of this Installer/User Manual and the installer’s contact details.
*
NOTE
:
Keep high voltage and low voltage cables at least 30mm apart.
Do not run high and low voltage cables in the same conduit.