JVA ELECTRIC FENCE SYSTEMS
30
JV
A Z114 L
CD K
eypad F
ea
tur
es
8. JVA Z114 LCD Keypad Features
8.1 Keypad status LEDs
The LCD keypad has two LEDs, Power and Arm, which act as follows:
• Power: On with Mains power, flashes on low battery.
• Arm: On When the energizer is armed (pulsing), flashes when in Low Power
Mode.
8.1.1 Arming/Disarming the Fence Using the Keypad
Enter your User PIN (Personal Identification Number: four digits long) and push the
# key. Make sure the red ARM light comes on and the keypad beeps twice to confirm
that the system is armed.
The fence will power up and if all is well (no faults) the system will be ready to deter
and detect.
To disarm the system, enter your User PIN and press #.
Note
: If there is an alarm sounding you will need to enter your PIN twice, once to
silence the alarm and once more to disarm.