9.2 Installation
The Remote control receiver unit requires 12V and 0V (GND) from the keypad bus,
and its output is shown wired to IN1.
Mount the receiver on the right hand side of the Z114 energizer. C12V and
0V (GND) from the KEYPAD terminals on the energizer to the right-most terminals of
the receiver, as per the diagram above.
Connect the IN1 terminals to the left-most terminals of the receiver.
Keep all connections away from any high voltage wiring, specifically the Fence Feed
connections coming from the left side of the energizer.
Remote Control Receiver Wiring Diagram
9.3 Operation and configuration
The remote controls come pre-configured to work with the receiver. Simply press the
LOCK key to arm the energizer. Press the
UNLOCK key to disarm.
Should a remote control become lost or stolen, it is possible to disassociate the
receiver with all remotes. To do this, press the button on the bottom right corner of
the receiver unit and hold for approximately 10 seconds. When the red light goes off
the receiver has wiped all associated remote controls from its memory.
To associate a remote control, press the button on the receiver once. The light will
come on momentarily. Next, press a button on the desired remote control. The
receiver light will begin flashing. Press the button on the receiver and the light will
stop flashing. Test the remote control by pressing a button. The receiver light will
flash, indicating it has successfully associated with the remote control. Repeat these
steps for any remaining remote controls that require (re)association.