5 Maintenance
The Z6 builds up deposits of limescale over time and automatically
prompts you to descale it when necessary. The degree of calcifica-
tion depends on the hardness of your water.
E
If you are using a CLARIS Smart filter cartridge, you will not be
prompted to descale.
If the descaling agent comes into contact with the skin or eyes, this
can cause irritation.
T
Avoid contact with the skin or eyes.
T
Rinse off the descaling agent with clean water. Should you get
any descaling agent in your eye, see a doctor.
If the wrong descaling agent is used, the machine could be dam-
aged and/or traces could be left behind in the water.
T
Use only original JURA maintenance products.
If the descaling operation is interrupted, there may be damage to
the machine.
T
Allow the descaling programme to run to the end.
If the descaling agent comes into contact with sensitive surfaces
(e.g. marble), damage cannot be ruled out.
T
Clean up any splashes immediately.
E
The descaling programme lasts approximately 45 minutes.
E
JURA descaling tablets are available from specialised dealers.
Precondition:
‘Decalcify machine’
is displayed.
T
Press the Rotary Switch.
‘Maintenance status’
T
Press the Rotary Switch.
‘Descale’
T
Press the Rotary Switch again.
T
Press the
‘Next’
button.
T
Press the
‘Start’
button.
‘Empty drip tray’
T
Empty the drip tray and coffee grounds container and put
them back into the machine.
‘Agent in tank’
Descaling the machine
J
CAUTION
CAUTION
CAUTION
CAUTION
Summary of Contents for Z6