IDP 75, 250, 800, and 8200 Installation Guide
48
IDP 75 Technical Specifications
IDP 75 Technical Specifications
Tables 17–20 list the physical, AC power, power cord, and environmental technical
specifications for the IDP 75 sensor.
Table 17: Physical Specifications
Specification
Value
Height
1 RU (1.3 inches)
Width
17 inches
Depth
15 inches
Weight
14.5 lbs
Table 18: AC Power Specifications
Specification
Nominal Value
Acceptable Range
AC input voltage
110/220 VAC, single phase
90 to 255 VAC
AC input line frequency
50/60 Hz
47 to 63 Hz
AC input current
4 A @ 110 VAC
2 A @ 220 VAC
Table 19: Power Cord Specifications
Country
Specifications
United States and Canada
UL-approved and CSA-certified
Flexible cord minimum spec: No. 18 (1.5 mm
2
), Type SVT
or SJT, 3-conductor
Current capacity of 10 A minimum
Earth-grounding attachment plug with NEMA 5-15P (10 A,
125 V) configuration
Table 20: Environmental Specifications
Specification
Value
Operating environment
0 to 35
o
C (ambient)
Non-operating environment
-10
o
to 70
o
C
Summary of Contents for IDP 250
Page 6: ...vi Table of Contents IDP 75 250 800 and 8200 Installation Guide...
Page 8: ...viii List of Figures IDP 75 250 800 and 8200 Installation Guide...
Page 10: ...x List of Tables IDP 75 250 800 and 8200 Installation Guide...
Page 14: ...IDP 75 250 800 and 8200 Installation Guide xiv Requesting Technical Support...
Page 20: ...IDP 75 250 800 and 8200 Installation Guide 6 IDP Configuration Basics...
Page 48: ...IDP 75 250 800 and 8200 Installation Guide 34 Checking the Status of Your Sensor...
Page 52: ...IDP 75 250 800 and 8200 Installation Guide 38 Reimaging the IDP Sensor...
Page 56: ...IDP 75 250 800 and 8200 Installation Guide 42 Replacing a Hard Drive IDP 800 and 8200 Only...
Page 68: ...IDP 75 250 800 and 8200 Installation Guide 54 Index...