0406
.GB
E 20
Battery parameters
Z
For trucks without a display instrument (CANDIS (
o
)) the code lock parameters can
only be set by the manufacturer's service department.
The parameters are set in the same way as for the travel parameters.
The following parameters can be entered.
Setting 0 / 1 is to be interpreted as: 0 = off 1 = on
No.
Function
Range
Setting value
Standard
Setting
value
Comments
Travel program 3
301 Acceleration
0 - 9
(0.13 – 1.88 m/s
2
)
8
(1.62 m/s
2
)
302 Coasting brake
0 - 9
(0.11 – 1.79 m/s
2
)
9
1.79 m/s
2
)
304 Maximum speed in tiller
direction via controller
0 - 9
(4.5 - 9 km/h)
8
(8.5 km/h)
Depending on travel
switch
308 Maximum speed in fork
direction via controller
0 - 9
(4.5 - 9 km/h)
8
(8.5 km/h)
Depending on travel
switch
No.
Function
Range
Setting value
Standard
Setting
value
Comments
Battery parameters
411 Battery type (normal/
high performance/dry)
0 - 2
0
0 = Normal (wet)
1 = Enhanced (wet)
2 = Dry
(maintenance-free)
412 Discharge monitor
function
0 / 1
1
0406
.GB
E 20
Battery parameters
Z
For trucks without a display instrument (CANDIS (
o
)) the code lock parameters can
only be set by the manufacturer's service department.
The parameters are set in the same way as for the travel parameters.
The following parameters can be entered.
Setting 0 / 1 is to be interpreted as: 0 = off 1 = on
No.
Function
Range
Setting value
Standard
Setting
value
Comments
Travel program 3
301 Acceleration
0 - 9
(0.13 – 1.88 m/s
2
)
8
(1.62 m/s
2
)
302 Coasting brake
0 - 9
(0.11 – 1.79 m/s
2
)
9
1.79 m/s
2
)
304 Maximum speed in tiller
direction via controller
0 - 9
(4.5 - 9 km/h)
8
(8.5 km/h)
Depending on travel
switch
308 Maximum speed in fork
direction via controller
0 - 9
(4.5 - 9 km/h)
8
(8.5 km/h)
Depending on travel
switch
No.
Function
Range
Setting value
Standard
Setting
value
Comments
Battery parameters
411 Battery type (normal/
high performance/dry)
0 - 2
0
0 = Normal (wet)
1 = Enhanced (wet)
2 = Dry
(maintenance-free)
412 Discharge monitor
function
0 / 1
1
Summary of Contents for ECE 118
Page 1: ...Operating instructions 51092878 ECE 118 G 08 06 07 08...
Page 3: ...0108 GB 0108 GB...
Page 7: ...0506 GB 2 0506 GB 2...
Page 9: ...0406 GB A 2 0406 GB A 2...
Page 13: ...0708 GB B 4 Dimensions b1 1006 850 0708 GB B 4 Dimensions b1 1006 850...
Page 17: ...0708 GB B 8 0708 GB B 8...
Page 27: ...0406 GB D 6 0406 GB D 6...
Page 34: ...E 7 0406 GB B R V 13 4 R V 0 3 5 B B B F 14 E 7 0406 GB B R V 13 4 R V 0 3 5 B B B F 14...
Page 51: ...0406 GB E 24 0406 GB E 24...
Page 81: ...0506 GB 18 0506 GB 18...