background image

eNet radio dimming actuator 1-gang mini

6

Parameter list

The device parameters can be changed with the eNet server:

Device and channels

Parameters

Setting options, Basic setting

Explanations

Function

Light, unused
Basic setting: Light

Light
The channel is integrated for
the "Lighting" central function
in the  eNet SMART HOME
app.

Unused
The channel is not displayed
in the eNet SMART HOME
app and is disabled for use in
the commissioning interface.

Operating mode

Normal operation
Continuous on
Continuous off
Basic setting: Normal Opera-
tion

Normal operation
The output can be operated
with radio transmitters and the
Prog button.

Continuous on
The output switches to con-
tinuously "On". All operations
of radio transmitters and the
Prog button are ignored.

Continuous off
The output switches to con-
tinuously "Off". All operations
of radio transmitters and the
Prog button are ignored.

Advanced device settings

Parameters

Setting options, Basic setting

Explanations

Manual commissioning

On, Off
Basic setting: On

Blocks manual commissioning
for the device channel.
Note: In the "Off" setting, the
device cannot be reset to the
factory setting.

Repeater mode

On, Off
Basic setting: Off

In addition to its other func-
tions, the device can be used
as a repeater. In the "On" set-
ting, the device repeats all the
received telegrams.

Channel settings

Parameters

Setting options, Basic setting

Explanations

Switch-on brightness

1...100 %
Basic setting: 100 %

During brief operation, the out-
put switches on at the set
switch-on brightness.
Note: If the value is above the
set maximum brightness or
below the minimum bright-

7 / 16

82580733

14.10.2019

J0082580733

Summary of Contents for FM J 50700 UP

Page 1: ...ty transformers ac cording to EN 61558 2 6 may be used These instructions are an integral part of the product and must remain with the end customer 2 Intended use Switching and dimming of lighting Ope...

Page 2: ...er operation and signalling could vary from what is de scribed here 4 Information for electrically skilled persons 4 1 Fitting and electrical connection DANGER Mortal danger of electric shock Before c...

Page 3: ...nsformers for halogen or LED lamps HV LED leading edge phase control Setting for incandescent lamps HV halogen lamps elec tronic transformers with halogen or LED lamps that can be dimmed according to...

Page 4: ...than 4 seconds The status LED 4 flashes after 3 seconds The actuator is in programming mode for approx 1 minute Switch radio transmitter to programming mode see radio transmitter instructions Trigger...

Page 5: ...for approx 5 seconds The actuator is reset to default setting Setting the minimum brightness The minimum brightness can be set within a range of approx 1 67 if e g the light flickers at low brightnes...

Page 6: ...dissipation Operate inductive transformers with at least 85 nominal load For ohmic inductive mixed load maximum 50 proportion of ohmic load Otherwise in correct calibration of the dimmer may result P...

Page 7: ...smitters and the Prog button are ignored Continuous off The output switches to con tinuously Off All operations of radio transmitters and the Prog button are ignored Advanced device settings Parameter...

Page 8: ...on after a delay Repeated switch on commands restart the delay time If the load has not yet been switched on due to the delay when a switch off com mand comes then the load will remain off Note The s...

Page 9: ...r remain on perman ently but only for the length of the run on time The run on time is restarted if actuation is repeated This parameter is directly connected to the Manual switch off of run on time p...

Page 10: ...l LED trailing edge phase con trol Leading edge phase control Trailing edge phase control Basic setting Universal Specifies the dimming prin ciple for the selected output Universal Automatic calibrati...

Page 11: ...value is above the set maximum brightness or below the minimum bright ness then the system will switch to the appropriate limit value Behaviour after the end of the disabling function On Off no chang...

Page 12: ...Basic setting 2 Specifies the priority for recall ing and removing a scene of type Restraint for the channel Activate forced operation brightness value 0 100 Basic setting 100 Defines the behaviour o...

Page 13: ...n is 0 Switch off brightness over shoot On Off Basic setting On Allows automatic switch off according to the brightness If the parameter is On then the light controller switches off automatically when...

Page 14: ...Check manufacturer s instructions Exchange lamps for another type Cause 2 Dimming principle and lamps do not optimally match Check operation in another dimming principle reduce connected load as well...

Page 15: ...current Cause 5 load failure Check load replace lamp For inductive transformers check primary fuse and replace if necessary Lamps flicker or buzz proper dimming not possible device buzzes Cause 1 Inco...

Page 16: ...dimming actuator 1 gang mini ALBRECHT JUNG GMBH CO KG Volmestra e 1 58579 Schalksm hle GERMANY Telefon 49 2355 806 0 Telefax 49 2355 806 204 kundencenter jung de www jung de 16 16 82580733 14 10 2019...