eNet radio dimming actuator 1-gang mini
All On and All Off buttons of a radio transmitter are disconnected automatically as soon as
the last connection to the radio transmitter is disconnected. Manual disconnection is not
possible.
Resetting actuator to default setting
All connections to radio transmitters are disconnected and parameters are reset to default set-
ting. If the operating mode switch is on PC, the dimming principle universal, automatic calibra-
tion to the load, is set.
The connections in the radio transmitters are preserved and must be deleted separately.
Load is switched off.
■
Press the Prog button for at least 20 seconds.
The status LED flashes after 4 seconds. After 20 seconds the status LED flashes faster.
■
Release Prog button and press briefly once again within 10 seconds.
The status LED flashes more slowly for approx. 5 seconds.
The actuator is reset to default setting.
Setting the minimum brightness
The minimum brightness can be set within a range of approx. 1...67 %, if, e.g. the light flickers
at low brightness or to compensate for differences in brightness.
■
Turn operating mode switch (1) to the min. position.
■
Adjust brightness with the radio transmitter.
■
Turn operating mode switch to the original position again.
When leaving the position min., the minimum brightness is saved.
Save switch-on brightness
■
Switch on light.
■
Adjust brightness with the radio transmitter.
■
Press button Prog (2) for longer than 4 seconds.
The light switches off briefly and then switches on again to the new switch-on brightness.
Switch-on brightness is saved.
Alternatively, the switch-on brightness can be saved with a radio transmitter, e.g. wall
transmitter.
5
Technical data
Rated voltage
AC 230 V~
Mains frequency
50 / 60 Hz
Power loss
max. 1.5 W
Standby power
max. 0.5 W
Ambient temperature
-25 ... +70 °C
Connected load at 45°C (Figure 4)
5 / 16
82580733
14.10.2019
J0082580733