eNet radio dimming actuator 1-gang mini

Connect 600 Watt LED lamps or compact fluorescent lamps at most per 16 ampere circuit
breaker. When connecting transformers, observe the data of the transformer manufac-
turer.

Our dimmers take into account the different electronic characteristics of most LED lamps
found on the market. However, it cannot be guaranteed that in individual cases the de-
sired results may not be achieved.

Figure 2: Clampable conductor cross-section

Connect the load according to connection diagram (Figure 1).

Insert the actuator in the appliance box in such a way that the Prog button (2) and Status
LED (3) are visible.

Figure 3: Operating mode switch

Switch position

Function/connectable loads

PC

Dimming principle and parameter set with eNet Server.*)

R,L,C
Universal

Automatic calibration to the load, leading edge phase control
or trailing edge phase control. Connection of incandescent
lamps, HV halogen lamps, electronic transformers for halo-
gen or LED lamps or dimmable inductive transformers for
halogen or LED lamps.

HV-

|

LED leading edge phase control

Setting for incandescent lamps, HV halogen lamps, elec-
tronic transformers with halogen or LED lamps that can be
dimmed according to the trailing edge phase control principle
or dimmable HV-LED or compact fluorescent lamps that can
be dimmed according to the leading edge phase control prin-
ciple. The connection of inductive transformers is not permit-
ted.

HV-

{

LED trailing edge phase control

Setting for incandescent lamps, HV halogen lamps, elec-
tronic transformers with halogen or LED lams that can be
dimmed according to the trailing edge phase control prin-
ciple, dimmable HV-LED or compact fluorescent lamps that
can be dimmed according to the trailing edge phase control
principle. The connection of inductive transformers is not per-
mitted.

min.

Setting of the minimum brightness

*)

If the operating mode switch is turned from the position PC, the operating mode and
parameters are set to the default setting. The settings made with the eNet Server will
be lost.
When setting the minimum brightness, the parameter settings remain unchanged.

Set the operating mode switch.

Switch on mains voltage.

3 / 16

82580733

14.10.2019

J0082580733

Summary of Contents for FM J 50700 UP

Page 1: ...ty transformers ac cording to EN 61558 2 6 may be used These instructions are an integral part of the product and must remain with the end customer 2 Intended use Switching and dimming of lighting Ope...

Page 2: ...er operation and signalling could vary from what is de scribed here 4 Information for electrically skilled persons 4 1 Fitting and electrical connection DANGER Mortal danger of electric shock Before c...

Page 3: ...nsformers for halogen or LED lamps HV LED leading edge phase control Setting for incandescent lamps HV halogen lamps elec tronic transformers with halogen or LED lamps that can be dimmed according to...

Page 4: ...than 4 seconds The status LED 4 flashes after 3 seconds The actuator is in programming mode for approx 1 minute Switch radio transmitter to programming mode see radio transmitter instructions Trigger...

Page 5: ...for approx 5 seconds The actuator is reset to default setting Setting the minimum brightness The minimum brightness can be set within a range of approx 1 67 if e g the light flickers at low brightnes...

Page 6: ...dissipation Operate inductive transformers with at least 85 nominal load For ohmic inductive mixed load maximum 50 proportion of ohmic load Otherwise in correct calibration of the dimmer may result P...

Page 7: ...smitters and the Prog button are ignored Continuous off The output switches to con tinuously Off All operations of radio transmitters and the Prog button are ignored Advanced device settings Parameter...

Page 8: ...on after a delay Repeated switch on commands restart the delay time If the load has not yet been switched on due to the delay when a switch off com mand comes then the load will remain off Note The s...

Page 9: ...r remain on perman ently but only for the length of the run on time The run on time is restarted if actuation is repeated This parameter is directly connected to the Manual switch off of run on time p...

Page 10: ...l LED trailing edge phase con trol Leading edge phase control Trailing edge phase control Basic setting Universal Specifies the dimming prin ciple for the selected output Universal Automatic calibrati...

Page 11: ...value is above the set maximum brightness or below the minimum bright ness then the system will switch to the appropriate limit value Behaviour after the end of the disabling function On Off no chang...

Page 12: ...Basic setting 2 Specifies the priority for recall ing and removing a scene of type Restraint for the channel Activate forced operation brightness value 0 100 Basic setting 100 Defines the behaviour o...

Page 13: ...n is 0 Switch off brightness over shoot On Off Basic setting On Allows automatic switch off according to the brightness If the parameter is On then the light controller switches off automatically when...

Page 14: ...Check manufacturer s instructions Exchange lamps for another type Cause 2 Dimming principle and lamps do not optimally match Check operation in another dimming principle reduce connected load as well...

Page 15: ...current Cause 5 load failure Check load replace lamp For inductive transformers check primary fuse and replace if necessary Lamps flicker or buzz proper dimming not possible device buzzes Cause 1 Inco...

Page 16: ...dimming actuator 1 gang mini ALBRECHT JUNG GMBH CO KG Volmestra e 1 58579 Schalksm hle GERMANY Telefon 49 2355 806 0 Telefax 49 2355 806 204 kundencenter jung de www jung de 16 16 82580733 14 10 2019...

Reviews: