– 106 –
12. Error E811
12-1) Excessive AC input voltage
1-A) There are variations or
Check the AC input power line.
Overvoltage error
(More than 280V)
unusual rise in the AC input
LED3 on SDC board: Flashing
power line.
8 times
1-B) The detector circuit is out of order.
Replace the SDC board.
13. Error E813
13-1) Insufficient AC input voltage
1-A) There are variations or unusual
Check the AC input power line.
Low voltage error
(Less than 160V)
drop in the AC input power line.
LED3 on SDC board: Flashing
6 times
1-B) 100V is used despite the 200V
Check the voltage setting (100V or 200V) in the
setting. (FLT board for 3-phase
FLT board.
specifications)
1-C) The detector circuit is out of
If everything is OK after the above checks, the SDC
order.
board is out of order.
14. Error E901
14-1)The main shaft motor driving
1-A) IPM heat generation is
Check whether electric box cooling is effective. Look
Main shaft motor IPM error
IPM in the SDC board generates
excessive.
for clogging around air suction holes and check the
LED3 on SDC board: Flashing
an error output
fan, etc.
5 times
1-B) The main shaft motor is out
Disconnect CN16 of the SDC board and check the
of order.
resistance among pins. [See the Servo Motor Circuit
Diagram.]
1-C) The driver circuit is out of order.
Replace the SDC board.
15. Error E903
15-1)No +85V power output of
1-A) Fuse F1 of the SDC board is
Check for the presence of short-circuiting in the +85V
Pulse motor source error
the SDC board available
broken.
system of the MAIN board. Eliminate the cause and
LED3 on SDC board: Flashing
replace the fuse.
11 times
1-B) Fuse F4 of the SDC board is
Replace the SDC board.
broken.
15-2)There is a deviation of more
2-A) The power circuit is out of order.
Replace the SDC board.
than
±
15% in the +85V sou-
rce of the SDC board.
16. Error E904
16-1)No +33V power output of the
1-A) Fuse F2 of the SDC board is
Check for the presence of short-circuiting in the +33V
Solenoid power source error
SDC board available
broken.
system of the MAIN board. Eliminate the cause and
LED3 on SDC board: Flashing
replace the fuse.
12 times
1-B) Fuse F5 of the SDC board is
broken.
16-2)There is a deviation of more
2-A) The power circuit is out of order.
Replace the SDC board.
than
±
15% in the +33V sou-
rce of the SDC board.
Trouble
Cause (1)
Cause (2)
Check and corrective measures
Summary of Contents for LK-1900A
Page 20: ... 16 10 Hook adjustment Standard Adjustment 0mm 0mm 7 5mm 0 05 0 1mm For DPX5 For DPX17 ...
Page 90: ... 86 Grease Grease Grease Grease Grease 8 Needle thread clamp mechanism area ...
Page 91: ... 87 Grease Grease A Grease Grease Grease Grease 9 LK 1901A relations ...
Page 92: ... 88 10 LK 1903A relations Grease Grease ...
Page 114: ... 111 12 Circuit diagrams 1 Block diagram A ...
Page 115: ... 112 2 Power supply circuit diagram A ...
Page 116: ... 113 3 Power supply circuit diagram B ...
Page 117: ... 114 4 Power supply circuit diagram C ...
Page 118: ... 115 5 Servo motor circuit diagram ...
Page 119: ... 116 6 Sensor pedal VR circuit diagram ...
Page 120: ... 117 7 MAIN PANEL board circuit diagram ...
Page 121: ... 118 8 Motor solenoid circuit diagram Thread trimmer Lifting the work clamp foot motor ...