![JUKI DDL-9000C Series Engineer'S Manual Download Page 26](http://html.mh-extra.com/html/juki/ddl-9000c-series/ddl-9000c-series_engineers-manual_2029706026.webp)
1) Bobbin case with idling prevention spring
(Drawing is for 40000264.)
B
A
C
(
1
)
(
2
)
(
3
)
(
4
)
❷
❶
Change the
height.
(4) Bobbin insertion
WARNING :
Be sure to turn the power OFF before the following work in order to prevent personal injury due to
unintentional starting of the sewing machine.
Standard adjustment
0.3±0.2mm
Ear
o For the bobbin case with idling prevention spring
Bobbin revolution
– 10 –