No.
Item
Setting range
Unit
Initial value
SMS
SSH
FMS
FSH SMS CE SSH CS FMS CE FSH CE
U035
Minimum speed of the pedal
The maximum number of revolutions during thread trimming
differs with the machine head.
150 to Max.
of thread
trimming
sti/min
200
200
200
200
200
200
200
200
U036
Speed during thread trimming
The maximum number of revolutions during thread trimming
differs with the machine head.
150 to Max.
of thread
trimming
sti/min
300
220
300
220
300
220
300
220
U037
Speed during soft start
The maximum number of revolutions during soft start differs with
the machine head.
The number of revolutions set with this memory switch is given
precedence even if it is lower than the lowest speed by pedal.
100 to Max
sti/min
800
800
800
800
800
800
800
800
U038
Speed during one-shot stitching
The maximum number of revolutions during soft start differs with
the machine head.
100 to Max
sti/min
2500
2500
2500
2500
2500
2500
2500
2500
U039
Start position of rotation
10 to 5000
-
600
600
600
600
600
600
600
600
U040
Start position of acceleration
10 to 1000
-
900
900
900
900
900
900
900
900
U041
Start position of lifting of presser foot
−
500
to −
10
-
−
100
−
100
−
100
−
100
−
100
−
100
−
100
−
100
U042
Start position of lowering of presser foot
10 to 500
-
300
300
300
300
300
300
300
300
U043
Start position of thread trimming
−
1000
to −
100
-
−
840
−
840
−
840
−
840
−
840
−
840
−
840
−
840
U044
Position that maximum sewing speed is reached
10 to 15000
-
4000
4000
4000
4000
4000
4000
4000
4000
U045
Pedal neutral-position correction value
−
150 to 150
-
0
0
0
0
0
0
0
0
U047
Presser-foot lift finishing position
The position to which the presser foot goes up when the back
part of the pedal is depressed to its first step. (1st-step spring
position)
−
1000 to
−
100
-
−
600
−
600
−
600
−
600
−
600
−
600
−
600
−
600
U049
Presser foot lowering time
The initial value differs with the machine head.
0 to 500
ms
100
100
100
100
100
100
100
100
U051
Correction of turning-ON of reverse feed stitching (at start)
−
50 to 50
Degree
0
0
0
0
0
0
0
0