− 70 −
No.
Item
Setting range
/
Edit unit
Initial value
Change-over of flap concealed stitching data edit reference
Making the flap concealed stitching data that is set from panel the
compensation value from the flap detecting end or the distance from
detectng sensor to sewng start s selected.
- - -
Flap detectng end
compensaton
Sensor
compensaton
L size data range enlargement
Enlarging/not enlarging L size data range to max. 220 mm + 15 mm is set.
- - -
Not enlargng
Enlargng
Selection of sewing speed of sewing machine setting
It is selected that either memory switch or pattern data performs
setting of sewing speed of sewing machine.
- - -
Memory swtch
Pattern data
Selection of reflecting tape check mode
ON/OFF of reflecting tape check mode is set.
When ON is set, the clamp foot is automatically comes lowered with
the first clamp foot advance motion after turning ON the power and
deterioration check of reflecting tape is performed.
*
Clamp foot is automatically lowered. Be sure to use this function
only in case of shim type.
- - -
OFF
ON
Selection of back tack return at sewing end compensation setting
It is selected that either memory switch or pattern data performs
setting of back tack return at sewing end compensation.
- - -
Memory swtch
Pattern data
Back tack return at sewing end compensation
Back tack return at sewng end compensaton s set.
*
It is possible to set only when
s set to the memory swtch
selecton.
−2.0 to
2.0
/
0.1mm
1.0mm
Selection of mode change-over button display in the pattern list
screen
Mode change-over button is displayed in the pattern list screen and
data of different mode can be selected.
- - -
Non-display
Dsplay