6
-
1
2
5
4
3
8
6
When opening valve
5
, be aware that the air-supplied mechanism is partly activated.
If the air supply source pulse is too large, even at the above setting value the emergency
signal might go off.
3-5. Installing the air hose and air gun and adjusting the pressure
(open)
(Shut)
!2
!0
!1
A
B
C
D
7
9
!3
(1) connecting the air
hose
) Connect fttng
1
to plug
2
. At ths tme, wrap seal-
ng tape or the lke round
the screw.
2) Insert ar hose
3
nto ft-
tng
1
and fasten them
wth hose band
4
.
(Use the correct ar hose
to match the fitting.)
(2) connecting the air gun
Insert the col tube of ar gun
7
nto quck-couplng jont
8
and put the ar gun on
L-shaped fitting
9
.
(3) opening/closing the valve
To open/close valve
5
, turn the valve untl t wll go no further (by 90 degrees of an
angle).
(4) adjusting the supply air pressure
) The operatng ar pressure should be set to 0.5 MPa.
2) Delberately open valve
5
.
3) Lft regulator knob
6
n drecton
A
. Turnng t n ths state wll change the sup-
ply ar pressure. Turn knob n drecton
C
(+) or n drecton
D
(–) so that black
pont of pressure gauge
!0
ndcates 0.5 MPa. After the adjustment, lower knob
6
n drecton
B
to securely lock t.
(5) Pressure drop signal adjustment
) Set the pressure at whch an emergency sgnal wll go off f the pressure drops below t.
2) The normal settng value s 0.4 MPa.
3) Insert a small screwdrver nto cap
!1
of pressure gauge
!0
, and adjust screw
!2
whch s nsde. Turn the
screw wth the screwdrver untl the green ponter ponts to 0.4 MPa.
(6) Discharging the drainage
) Remove the dran from regulator before use to dscharge water (by loosenng knob
!3
).
2) Water adversely affects the ar control components. It s therefore necessary to carefully remove the water.
3) If the ar pressure n regulator drops, the pressure gauge swtch comes on to cause an error.