MANUAL

P5335

Universal Single- and Double-channels Transmitters

to DIN Rail with HART Communication

Transmitters - NB1015EN - 2017/11

JSP Industrial Controls

JSP, s.r.o. 

PHONE / FAX 

 

JSP Slovakia s.r.o. 

PHONE / FAX 

Raisova 547 

+420 493 760 811 

[email protected] 

Karloveská 63 

+421 2 6030 1080 

[email protected] 

CZ-506 01 Jičín 

+420 493 760 820 

www.jsp.cz 

SK-841 04 Bratislava 

+421 2 6030 1089 

www.jsp.sk 

• Universal input for all common resistance 
  and thermocouple temperature sensors, 
  linear resistance and mV
• Accuracy 0.05 %
• Measurement of difference or average 
  of two sensors
• Current output signal 4 to 20 mA 
  with HART communication 

• Galvanic isolation 1.5 kVAC
• Removable spring or screw terminals
• Width from 12 mm per channel
• High immunity against interference 
  (industrial environment)
• Intrinsically safe version 
 

 II (1) G [Ex ia Ga] IIC,  

 

 II (1) D [Ex ia Da] IIIC

Summary of Contents for P5335

Page 1: ...820 www jsp cz SK 841 04 Bratislava 421 2 6030 1089 www jsp sk Universal input for all common resistance and thermocouple temperature sensors linear resistance and mV Accuracy 0 05 Measurement of dif...

Page 2: ...allation operation and maintenance 5 4 1 Installation and commissioning 5 4 2 Measurement of thermocouple temperature sensors using transmitter P5335 Lxx for a DIN rail 6 4 3 Description of setting an...

Page 3: ...balen v ochrann m krytu a za p edpokladu identifika n m t tkem se zna kou v stupn kontroly V robek nesm b t vystaven p m mu d vibrac a r z p i p eprav 1 5 Storage The products shall be stored at tempe...

Page 4: ...sensors In other cases the resistance of input wires is compensated automatically In case of three and four wire connection there can be entered the maximal values of resistance of the line and the m...

Page 5: ...II 1 D Ex ia Da IIIC The transmitter P5335 for installation for DIN rail may not be installed in any explosion hazard environment This restriction also applies to version P5335 Lxx EI1 Only input and...

Page 6: ...o the transmitter terminals or in a remote terminal box that is connected with the transmitter using a copper line In both cases it is necessary to install the compensation sensor so that it measures...

Page 7: ...setting and control can be found in the instructions manual to the configurator The transmitter in design EI1 can be configured using the communicator HARTConf only if the transmitter communicator an...

Page 8: ...m C Voltage 10 V 0 5 V C Characteristics Linear with temperature or linear with input quantity other upon request Adjustability of the range 16 bit P estavitelnost rozp t 1 to 100 of the basic range...

Page 9: ...ompensation terminal CTB1 L11 Single channel transmitter with removable screw terminals L12 Single channel transmitter with removable spring terminals L20 Double channel transmitter with removable scr...

Page 10: ...10 Universal Single and Double channels Transmitters to DIN Rail with HART Communication 8 Appendix 8 1 Declaration of conformity explosion hazard environment version code EI1...

Page 11: ...JSP Industrial Controls JSP s r o Raisova 547 506 01 Ji n Czech Republic 420 493 760 811 export jsp cz www jsp cz Your Supplier Contacts...

Reviews: