- 9 -
Universal Single- and Double-channels Transmitters to DIN Rail with HART Communication
6. Tests, certificates and standards
6.1 Tests and certificates
Electromagnetic compatibility
emission and immunity acc. to EN 61326-1
Intrinsical safety (version EI1)
II (1) G [Ex ia Ga] IIC,
II (1) D [Ex ia Da] IIIC
6.2 Standards
Transmitter is designed and manufactured according these
standards:
EN 61326-1, EN 60079-0, EN 60079-11, EN 60079-26
6.3 Marking and type tag information
Standard version:
P5335
type number
Model:
model
S/No:
serial number
Czech Republic
country of origin
logo of JSP, s.r.o.
www.jsp.cz
webside adress
Tag of model EI1 further includes:
II (1) G [Ex ia Ga] IIC
II (1) D [Ex ia Da] IIIC
FTZÚ 08 ATEX 0032
year of manufacture
6.4 Limiting conditions of use of a transmitter
in an intrinsically safe version (code EI1)
Output
(current loop, terminals 11, 12 or terminals 21, 22):
U
i
= 30 VDC
I
i
= 120 mA
P
i
= 0.84 W
L
i
= 10 μH
C
i
= 1 nF
Input for sensor
(terminals 13, 14, 15, 16 or terminals 23, 24, 25, 26):
U
o
= 9.6 VDC
I
o
= 28 mA
P
o
= 0.067 W
L
o
= 35 mH
C
o
= 3.5 μF
The sensor circuit is not infallibly galvanic isolated from the
supply output circuit. However, the galvanic isolation between
the circuits is capable of withstanding a test voltage of 500
VAC during 1 minute.
7. Ordering
7.1 Ordering table
Type
Description
P5335
Single-channel and double-channel universal transmitter for a DIN rail with HART communication
Code
Version
L10
Single-channel transmitter with removable screw terminals (plus compensation terminal CTB1)
L11
Single-channel transmitter with removable screw terminals
L12
Single-channel transmitter with removable spring terminals
L20
Double-channel transmitter with removable screw terminals (plus compensation terminals CTB1 and CTB2)
L21
Double-channel transmitter with removable screw terminals
L22
Double-channel transmitter with removable spring terminals
Code
Setting requirements
NR
Without requirements for the range and input setting (preset - Pt100, 3-wire sensor connection, 0 to 100 °C)
QR
Range and other parameters setting according to configuration sheet DB0998
Code
Calibration
KPP5
Certificate of calibration, transmitter calibration in five equally spaced points in the set range
Code
Optional version
EI1
1)
ATEX (Ex) II (1) G [Ex ia Ga] IIC, (Ex) II (1) D [Ex ia Da] IIIC
Code
Optional accessories
CTB1
Compensation terminal for measuring thermocouple sensors, channel No.1
CTB2
Compensation terminal for measuring thermocouple sensors, channel No.2
HARTWinCom
Set of PC configuration software HARTWinConf (CZ+EN) and modem HARTMod
HARTConf
HART-USB modem and field handheld configurator for transmitters with HART and LHP communication,
function of transmitter supply, supplied from USB or accumulator, charged from USB
HARTMod
Miniature HART modem with galvanic isolation
5 years warranty
Example of order: P5335 L10 NR HARTConf
For code QR configuration sheet DB0998 is required to the order.
• ... Ex stock version ° ... Marked version can be dispatched up to 5 working days (with calibration up to two weeks)
1)
…Transmitter must not be placed in potentially explosive atmospheres. In a potentially explosive atmosphere can lead only
input and output wires.
•
•
•
•
•
•
•
•
•
•
•
°
•
•