Universal Single- and Double-channels Transmitters to DIN Rail with HART Communication

Basic ranges:

 
Type

Minimal
value

Maximal 
value

Minimal 
Span

 
Standard

Pt100, Pt1000

-200 °C

850 °C

10 °C

EN 60751

Ni100

-60 °C

250 °C

10 °C

DIN 43760

Thermocouple B

+400 °C

1820 °C

100 °C

IEC 584

Thermocouple E

-100 °C

1000 °C

50 °C

IEC 584

Thermocouple J

-100 °C

1200 °C

50 °C

IEC 584

Thermocouple K

-180 °C

1372 °C

50 °C

IEC 584

Thermocouple L

-100 °C

900 °C

50 °C

DIN 43710

Thermocouple N

-180 °C

1300 °C

50 °C

IEC 584

Thermocouple R

-50 °C

1760 °C

100 °C

IEC 584

Thermocouple S

-50 °C

1760 °C

100 °C

IEC 584

Thermocouple T

-200 °C

400 °C

50 °C

IEC 584

Thermocouple U

-200 °C

600 °C

50 °C

DIN 43710

W3

0 °C

2300 °C

100 °C

ASTM E988-90

W5

0 °C

2300 °C

100 °C

ASTM E988-90

Linear resistance

0 Ohm

7000 Ohm

25 Ohm

Voltage

-800 mV

800 mV

2.5 mV

Output

Output signal:

 

Two-wire current 4 to 20 mA or 20 to 4 mA with HART  

 

protocol

Total accuracy (higher value applies):

 
Input

Basic 
accuracy

Temperature 
coefficient

 
All inputs

≤ ±0.05 % 
of span

≤ ±0.005 % 
of span / °C

Pt100, Pt1000

≤ ±0.1 °C

≤ ±0.005 °C / °C

Ni100

≤ ±0.2 °C

≤ ±0.005 °C / °C

TC, type 
E, J, K, L, N, T, U

 
≤ ±0.5 °C

 
≤ ±0.025 °C / °C

TC, type 
B, R, S, W3, W5

 
≤ ±1 °C

 
≤ ±0.1 °C / °C

Linear resistance

≤ ±0.1 

≤ ±5 m

Ω / °C

Voltage

≤ ±10 μV

≤ ±0.5 μV / °C

Characteristics:

 

Linear with temperature or linear with input quantity,  

 

other upon request

Adjustability of the range: 

 

16 bit

Přestavitelnost rozpětí:

 

1 % to 100 % of the basic range

Time constant (95 %): 

 

adjustable 1 to 60 s

Minimal output span: 

 

 

 

 

16 mA

Renewal period:  

 

 

440 ms (660 ms for difference two sensors)

Fixed output:

 

in the range 4 to 20 mA

Load resistance of output: 

 

 

 

≤ (V

supply

 - 8) / 0.023 [

]

Output stability:  

 

 

 

 

 

< ±0.01 % of span / 100 

Electrical strength of isolation between input and output 
circuit:

 

test 

 

1,5 kVAC

 

constatnt 

50 VAC

Electrical  strength  between  channels  (only  for  double-
channel version):

 

test 

2.5 kVAC

5.2 Supplementary parameters

Output current limitation:   

 

 

Signal 3.8 to 20.5 mA according to NAMUR NE43

  

Limitation of error current to approximately 23 mA

Supply voltage effects: 

 

< 0.005 % of span / VDC

EMC effects (immunity):   

 

< ±0.1 % of span

Extended EMC immunity (NAMUR NE21, A criterion, burst):

 

< ±1 % of span 

Indication of sensor error:

 

Optionally  by  current  >  21  mA  or  <  3.6  mA  acc.  to  

 

NAMUR NE43, or optionally in range 3.5 to 23 mA

Current of sensor at sensor error detection: 

 

33 μA

Sensor error detection:

 

resistance ranges: if beginning of measure range 

 

  > 30 

 or adequate temperature

 

voltage ranges:   if beginning of measure range 

 

 

 

 > 5 mV or adequate temperature

Warming time:   

 

 

30 s

Error checking EEPROM:  

 

< 10 s

Output signal at EEPROM error: 

 

≤ 3.5 mA

Summary of Contents for P5335

Page 1: ...820 www jsp cz SK 841 04 Bratislava 421 2 6030 1089 www jsp sk Universal input for all common resistance and thermocouple temperature sensors linear resistance and mV Accuracy 0 05 Measurement of dif...

Page 2: ...allation operation and maintenance 5 4 1 Installation and commissioning 5 4 2 Measurement of thermocouple temperature sensors using transmitter P5335 Lxx for a DIN rail 6 4 3 Description of setting an...

Page 3: ...balen v ochrann m krytu a za p edpokladu identifika n m t tkem se zna kou v stupn kontroly V robek nesm b t vystaven p m mu d vibrac a r z p i p eprav 1 5 Storage The products shall be stored at tempe...

Page 4: ...sensors In other cases the resistance of input wires is compensated automatically In case of three and four wire connection there can be entered the maximal values of resistance of the line and the m...

Page 5: ...II 1 D Ex ia Da IIIC The transmitter P5335 for installation for DIN rail may not be installed in any explosion hazard environment This restriction also applies to version P5335 Lxx EI1 Only input and...

Page 6: ...o the transmitter terminals or in a remote terminal box that is connected with the transmitter using a copper line In both cases it is necessary to install the compensation sensor so that it measures...

Page 7: ...setting and control can be found in the instructions manual to the configurator The transmitter in design EI1 can be configured using the communicator HARTConf only if the transmitter communicator an...

Page 8: ...m C Voltage 10 V 0 5 V C Characteristics Linear with temperature or linear with input quantity other upon request Adjustability of the range 16 bit P estavitelnost rozp t 1 to 100 of the basic range...

Page 9: ...ompensation terminal CTB1 L11 Single channel transmitter with removable screw terminals L12 Single channel transmitter with removable spring terminals L20 Double channel transmitter with removable scr...

Page 10: ...10 Universal Single and Double channels Transmitters to DIN Rail with HART Communication 8 Appendix 8 1 Declaration of conformity explosion hazard environment version code EI1...

Page 11: ...JSP Industrial Controls JSP s r o Raisova 547 506 01 Ji n Czech Republic 420 493 760 811 export jsp cz www jsp cz Your Supplier Contacts...

Reviews: