Operation
4-3
DSC alert sounds
The following table summarizes the alert characteristics when communicating particularly in the
DSC mode.
Reason for the alert
Sound
Increase
Shutdown
Receiving a new distress
event
Two tones of
2200Hz(250ms) and 1300Hz(250ms)
Yes
Manually
Acknowledging a received
distress event
Two tones of
2200Hz(500ms) and 1300Hz(500ms)
No
Manually
Acknowledging a sent own
distress event
Two tones of
2200Hz(500ms) and 1300Hz(500ms)
No
Manually
Receiving a new urgency
event
Intermittent tones of
2200Hz(250ms) and silence(250ms)
Yes
Manually
Acknowledging a sent
urgency event
Intermittent tones of
2200Hz(500ms) and silence(500ms)
No Manually
Receiving a new safety or
routine event
Two tones of
784Hz(1s) and 392Hz(1s)
Yes
Automatically
(10s)
Acknowledging a sent safety
or routine event
Intermittent tones of
784Hz(1s) and silence(1s)
No Automatically
(10s)
Receiving a DSC message
pertinent to an ongoing event
Intermittent tones of
494Hz(100ms), silence(100ms) and
494Hz(1s)
No
Automatically
(1 cycle)
Pressing the dedicated
distress button
An intermittent tone of
2000Hz(500ms) and silence(500ms)
No
---
If receiving a DSC message with the ECC error, the alert is stopped automatically.
However, if the same DSC messages are received repeatedly and the every error is
corrected at last, the original alert may be sounded.
BAM alert sounds
In addition to DSC alerts, BAM (Bridge Alert Management) uses two short audible signals.
For details, see "6.3.5 BAM Alert sound".
Note
Summary of Contents for JSS-2150 -
Page 2: ......
Page 12: ...x NFC 2250 2500 Antenna tuner NBB 714 724 Battery charger...
Page 48: ...Equipment Overview 1 18 Battery Charger NBB 724 Unit mm Weight Approx 12 kg...
Page 66: ...Installation 3 2...
Page 176: ...Maintenance Inspection 6 24...
Page 180: ...Disposal 8 2...
Page 212: ...Options Operation 10 16...
Page 240: ...Appendix 11 28...
Page 242: ......
Page 244: ......
Page 246: ......
Page 247: ......