Maintenance & Inspection
6-13
6.4.2 Maintenance Information table
The Maintenance information displayed by this equipment is as follows:
(1) JSS-2150
MI
Number
Source
Unit
Display
Contents
Troubleshooting
Procedure
001 PA
Overcurrent
Detected an overcurrent (20 A or
more) in the PA power supply.
Re-tune or operate on
another frequency.
007
PA
SWR/Overload
Detected the condition SWR > 3.
Re-tune or operate on
another frequency.
008 PA
High
temperature
Detected an out-of-range temperature
(110°C or more) at the radiator.
Stop transmission, or
reduce output.
010
PA
RBK overcurrent
Detected RBK overcurrent.
Please contact JRC or
our agency.
055
PA
24V low voltage
Detected a drop (12V or less) in
the PA power supply voltage.
Please contact JRC or
our agency.
091
PA
EEPROM
Detected a memory error.
Please contact JRC or
our agency.
017 ATU
ATU
lost
Detected a serial communication
error with the tuner.
Please contact JRC or
our agency.
018 ATU
High
voltage
Detected a high voltage (3.5 kV or
more) in antenna output.
Re-tune, or reduce
output.
019 ATU
High
temperature
Detected an out-of-range temperature
(70°C or more) inside the enclosure.
Stop transmission, or
reduce output.
020 TRX
DISP_KEY
Detected abnormal ON signal at the
PTT or Ext key of the controller.
Please contact JRC or
our agency.
021 TRX
EXT_KEY
Detected abnormal ON signal at the
transceiver external key.
Please contact JRC or
our agency.
022 TRX
SEL_BK
Detected abnormal ON signal at
the Selcall key on the transceiver.
Please contact JRC or
our agency.
023 TRX
-BK
Detected the -BK output error
during transmission.
Please contact JRC or
our agency.
024 TRX
PLL
unlock
Detected PLL unlock for the DDS
or DUC clock.
Please contact JRC or
our agency.
030
WKR
MODEM
PLL unlock
Detected PLL unlock for the DDS
clock.
Please contact JRC or
our agency.
031
WKR
MODEM
MCDSP WDT
Detected MCDSP malfunction.
Please contact JRC or
our agency.
032
WKR
MODEM
VDSP WDT
Detected VDSP malfunction.
Please contact JRC or
our agency.
033
WKR
MODEM
MMSI lost
Detected non-registration or loss
of the ship's MMSI.
Please contact JRC or
our agency.
094
WKR
MODEM
Memory
Detected a memory error.
Please contact JRC or
our agency.
035
Controller
CTRL1 RBK OC
Detected an overcurrent on the
RBK circuit of controller 1.
Please contact JRC or
our agency.
036 Controller
CTRL1
PTT
Detected an error on the PTT control
line of controller 1.
Please contact JRC or
our agency.
037 Controller
CTRL1
CW
KEY
Detected an error on the CW key control
line of controller 1.
Please contact JRC or
our agency.
038
Controller
CTRL1 EXT KEY
Detected an error on the external key
control line of controller 1.
Please contact JRC or
our agency.
039
Controller
CTRL2 RBK OC
Detected an overcurrent on the
RBK circuit of controller 2.
Please contact JRC or
our agency.
040 Controller
CTRL2
PTT
Detected an error on the PTT control
line of controller 2.
Please contact JRC or
our agency.
041 Controller
CTRL2
CW
KEY
Detected an error on the CW key control
line of controller 2.
Please contact JRC or
our agency.
042
Controller
CTRL2 EXT KEY
Detected an error on the external key
control line of controller 2.
Please contact JRC or
our agency.
047 Controller
PA
lost
Detected a serial communication
error with the PA.
Please contact JRC or
our agency.
048 Controller
TRX
lost
Detected a serial communication
error with the TRX.
Please contact JRC or
our agency.
Summary of Contents for JSS-2150 -
Page 2: ......
Page 12: ...x NFC 2250 2500 Antenna tuner NBB 714 724 Battery charger...
Page 48: ...Equipment Overview 1 18 Battery Charger NBB 724 Unit mm Weight Approx 12 kg...
Page 66: ...Installation 3 2...
Page 176: ...Maintenance Inspection 6 24...
Page 180: ...Disposal 8 2...
Page 212: ...Options Operation 10 16...
Page 240: ...Appendix 11 28...
Page 242: ......
Page 244: ......
Page 246: ......
Page 247: ......