3-3
Procedures
1 Check that the ship’s mains are turned on.
2 Press the [STBY] key.
The system is turned on, and the preheating time is displayed.
Preheat is indicated upper left of the display.
3 Wait until the preheating time is over.
When the preheating time is over, the preheating time screen disappears, and Preheat
upper left of the display changes to Standby .
4 Press the [TX / PRF] key.
The radar will start transmission and the antenna will start rotating.
Standby upper left of the display changes to Transmit .
Note:
The radar does not start transmission if you Press the
[TX / PRF]
key while Preheat is
indicated.
3.1.2 Observe and Adjust Video
Procedures
1 Press the [RANGE+] key or [RANGE-] key to set the range to the scale
required for target observation.
2 Turn the dials [GAIN / PL], [AUTO-SEA], and [AUTO-RAIN] to obtain
the clearest targets.
Refer to
[GAIN/PL]
→
3-7P
[AUTO-SEA]
→
3-7P
[AUTO-RAIN]
→
3-9P
for how to use each dial.
For how to adjust video, see Chapter 3.2.
3.1.3 Acquire and Measure Data
For details on how to acquire data and measure, see Section 4 "Measurement of range and bearing."
3.1.4 Display and Measure with Reference to CCRP
The radar video, range, bearing, Target Tracking and AIS data display etc... are displayed with
reference to CCRP (Consistent Common Reference Point).
If scanner is switched, these data are measured from CCRP.
If some kind of functions set scanner position to outside of the PPI range, these data except Target
Tracking and AIS data are displayed with reference to scanner position.
For how to setting CCRP, see the section 7.1.9.
Summary of Contents for JMA-5912-6
Page 2: ......
Page 17: ...xi NKE 2103 6 Scanner Unit NKE 2254 7 9 Scanner Unit Warning Label Warning Label...
Page 18: ...xii NKE 1130 Scanner Unit NQE 3151A Junction Box Warning Label Warning Label...
Page 19: ...xiii NQE 3141 4A 8A Interswitch Unit NBA 5111 Power Supply Warning Label Warning Label...
Page 20: ...xiv NQE 3167 Power Control Unit Warning Label...
Page 22: ...xvi Scanner Unit Type NKE 2254 9 9 feet NDC 1477 Radar Process Unit Desktop Type...
Page 23: ...xvii NWZ 170 Monitor Unit Desktop Type NCE 5171 Operation Unit Desktop Type...
Page 40: ......
Page 48: ...1 7 Fig 1 1 Outside Drawing of NKE 2103 6 SCANNER UNIT...
Page 49: ...1 8 1 4 Exterior Drawings y 1 Fig 1 2 Outside Drawing of NKE 2254 7 SCANNER UNIT...
Page 50: ...1 9 Fig 1 3 Outside Drawing of NKE 2254 9 SCANNER UNIT...
Page 51: ...1 10 1 4 Exterior Drawings y 1 Fig 1 4 Outside Drawing of NKE 1130 SCANNER UNIT...
Page 52: ...1 11 Fig 1 5 Outside Drawing of NWZ 170 MONITOR UNIT Option...
Page 54: ...1 13 Fig 1 7 Outside Drawing of NDC 1477 RADAR PROCESS UNIT...
Page 55: ...1 14 1 4 Exterior Drawings y 1 Fig 1 8 Outside Drawing of NCE 5171 OPERATION UNIT...
Page 56: ...1 15 Fig 1 9 Outside Drawing of NQE 3151A JUNCTION BOX...
Page 57: ...1 16 1 4 Exterior Drawings y 1 Fig 1 10 Outside Drawing of NQE 3141 4A INTERSWITCH UNIT Option...
Page 58: ...1 17 Fig 1 11 Outside Drawing of NQE 3141 8A INTERSWITCH UNIT Option...
Page 60: ...1 19 Fig 1 13 Outside Drawing of NQE 3167 POWER CONTROL UNIT Option...
Page 68: ...2 3 Lower left of the display Upper right of the display...
Page 242: ......
Page 328: ...7 9...
Page 384: ......
Page 402: ......
Page 421: ...APPENDIX...
Page 422: ......
Page 438: ...32bit bus BP BZ VD TI MTR PWRCNT P12V 12V RGB Fig 2 Block Diagram of JMA 5932 12 RADAR...
Page 442: ...Fig 6 Terminal Board Connection Diagram of RADAR and INTERSWITCH Unit Option...
Page 443: ...Fig 7 Power System Diagram of JMA 5912 6 JMA 5922 7 9 RADAR...
Page 445: ...Fig 9 Internal Connection Diagram of NDC 1477 RADAR PROCESS UNIT...
Page 446: ...Fig 10 Internal Connection Diagram of NQA 2123 INTERFACE UNIT...
Page 447: ...Fig 11 Internal Connection Diagram of NCE 5171 OPERATION UNIT...
Page 465: ......