4-15
[II] Operating Variable Range Marker (VRM)
Procedures
1 Put the cursor on VRM1 or VRM2, and press the [ENT] key.
When the cursor is moved to it, VRM1 or VRM2 is shown at the upper right
of the cursor. The VRM becomes operable when the
[ENT]
key is pressed.
2 Move the cursor to the range to be set.
The VRM will move as the cursor moves.
3 Press the [ENT] key.
The VRM will be fixed.
[III] Operating EBL and VRM Concurrently (EBL and VRM)
Procedures
1 Put the cursor on the intersection marker (
○
or
●
), and
press
the
[ENT] key.
When the cursor is moved to it, EBL1 VRM1 or EBL2 VRM2 is shown at the
upper right of the cursor. The EBL and VRM become operable when the
[ENT]
key
is pressed.
2 Move the cursor to the bearing / range to be set.
The EBL and VRM will move as the cursor moves.
3 Press the [ENT] key.
The EBL and VRM will be fixed.
[IV] Operating Parallel Index Lines (PI)
To change the direction of parallel index lines
Procedures
1 Put the cursor on near the center of line, and press the [ENT]
key.
When the cursor is moved there, it will turn into "
" and PI will be displayed at
the upper right of the cursor. The parallel index lines become operable when the
[ENT]
key is pressed.
2 Move the cursor to the direction to be set.
The parallel index lines will change the direction as the cursor moves.
3 Press the [ENT] key.
The parallel index lines will be fixed.
Summary of Contents for JMA-5912-6
Page 2: ......
Page 17: ...xi NKE 2103 6 Scanner Unit NKE 2254 7 9 Scanner Unit Warning Label Warning Label...
Page 18: ...xii NKE 1130 Scanner Unit NQE 3151A Junction Box Warning Label Warning Label...
Page 19: ...xiii NQE 3141 4A 8A Interswitch Unit NBA 5111 Power Supply Warning Label Warning Label...
Page 20: ...xiv NQE 3167 Power Control Unit Warning Label...
Page 22: ...xvi Scanner Unit Type NKE 2254 9 9 feet NDC 1477 Radar Process Unit Desktop Type...
Page 23: ...xvii NWZ 170 Monitor Unit Desktop Type NCE 5171 Operation Unit Desktop Type...
Page 40: ......
Page 48: ...1 7 Fig 1 1 Outside Drawing of NKE 2103 6 SCANNER UNIT...
Page 49: ...1 8 1 4 Exterior Drawings y 1 Fig 1 2 Outside Drawing of NKE 2254 7 SCANNER UNIT...
Page 50: ...1 9 Fig 1 3 Outside Drawing of NKE 2254 9 SCANNER UNIT...
Page 51: ...1 10 1 4 Exterior Drawings y 1 Fig 1 4 Outside Drawing of NKE 1130 SCANNER UNIT...
Page 52: ...1 11 Fig 1 5 Outside Drawing of NWZ 170 MONITOR UNIT Option...
Page 54: ...1 13 Fig 1 7 Outside Drawing of NDC 1477 RADAR PROCESS UNIT...
Page 55: ...1 14 1 4 Exterior Drawings y 1 Fig 1 8 Outside Drawing of NCE 5171 OPERATION UNIT...
Page 56: ...1 15 Fig 1 9 Outside Drawing of NQE 3151A JUNCTION BOX...
Page 57: ...1 16 1 4 Exterior Drawings y 1 Fig 1 10 Outside Drawing of NQE 3141 4A INTERSWITCH UNIT Option...
Page 58: ...1 17 Fig 1 11 Outside Drawing of NQE 3141 8A INTERSWITCH UNIT Option...
Page 60: ...1 19 Fig 1 13 Outside Drawing of NQE 3167 POWER CONTROL UNIT Option...
Page 68: ...2 3 Lower left of the display Upper right of the display...
Page 242: ......
Page 328: ...7 9...
Page 384: ......
Page 402: ......
Page 421: ...APPENDIX...
Page 422: ......
Page 438: ...32bit bus BP BZ VD TI MTR PWRCNT P12V 12V RGB Fig 2 Block Diagram of JMA 5932 12 RADAR...
Page 442: ...Fig 6 Terminal Board Connection Diagram of RADAR and INTERSWITCH Unit Option...
Page 443: ...Fig 7 Power System Diagram of JMA 5912 6 JMA 5922 7 9 RADAR...
Page 445: ...Fig 9 Internal Connection Diagram of NDC 1477 RADAR PROCESS UNIT...
Page 446: ...Fig 10 Internal Connection Diagram of NQA 2123 INTERFACE UNIT...
Page 447: ...Fig 11 Internal Connection Diagram of NCE 5171 OPERATION UNIT...
Page 465: ......