A-19
Appendix A
Alert and Maintenance INFO List
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
APP A
23
24
25
Message Explanation
Advice
DSC(Communication
failed, Main LAN)
Communication with DSC
cannot be performed via
Main LAN.
Check the condition of DSC and Main LAN.
If it cannot be recovered after you check the
connection of the equipment cable in
power-off status and restart, turn off the
power of the device and contact your
distributor.
DSC(Communication
failed, Sub LAN)
Communication with DSC
cannot be performed via
Sub LAN.
Check the condition of DSC and Sub LAN.
If it cannot be recovered after you check the
connection of the equipment cable in
power-off status and restart, turn off the
power of the device and contact your
distributor.
DSP(Heading Data)
There is an error in the
heading data received by
DSP.
Restart the power.
If it cannot be recovered after three times of
restart, turn off the device and contact the
distributor.
Dual Axis SOG(invalid)
There is a format error or
a status error of the data.
Check the sensor condition.
Dual Axis SOG(not
plausible)
There is a range error of
the data.
Check the sensor condition.
Dual Axis
SOG(unavailable)
The data cannot be
received.
Check the condition of the sensor and the
communication path.
Echo Sounder #n
(Communication failed,
Direct)
Communication with Echo
Sounder cannot be
performed via Serial.
Check the condition of Echo Sounder and
Serial.
If it cannot be recovered after you check the
connection of the equipment cable in
power-off status and restart, turn off the
power of the device and contact your
distributor.
Echo Sounder #n
(Communication failed,
Main LAN)
Communication with Echo
Sounder cannot be
performed via Main LAN.
Check the condition of Echo Sounder and
Main LAN.
If it cannot be recovered after you check the
connection of the equipment cable in
power-off status and restart, turn off the
power of the device and contact your
distributor.
Echo Sounder #n
(Communication failed,
Sub LAN)
Communication with Echo
Sounder cannot be
performed via Sub LAN.
Check the condition of Echo Sounder and
Sub LAN.
If it cannot be recovered after you check the
connection of the equipment cable in
power-off status and restart, turn off the
power of the device and contact your
distributor.
Engine Telegraph #n
(invalid)
There is a format error or
a status error of the data.
Check the sensor condition.
Engine Telegraph #n
(not plausible)
There is a range error of
the data.
Check the sensor condition.
Engine Telegraph #n
(unavailable)
The data cannot be
received.
Check the condition of the sensor and the
communication path.
Engine/Propeller #n
(invalid)
There is a format error or
a status error of the data.
Check the sensor condition.
Summary of Contents for ECDIS
Page 2: ......
Page 10: ...Contents 8 ...
Page 40: ...Section 17 Adjusting and Setting up Equipment for Services 17 30 ...
Page 132: ...Section 20 Failures and After Sale Services 20 20 ...
Page 152: ...Section 22 Specifications 22 18 ...
Page 212: ...Appendix B Menu List and Materials B 32 B 1 16 Code Input Password ECDIS CONNING ...
Page 368: ...Appendix B Menu List and Materials B 188 ...
Page 369: ......