Appendix A
Alert and Maintenance INFO List
A-4
A.2 Warnings
Message Subject
Explanation
Category
Actual course change
TCS
Arrival at Wheel Over Line alarm
30 seconds prior to the arrival at WOL
A
AIS(invalid)
INS
AIS data validity error
B
AIS(unavailable)
INS
AIS data not received yet
B
AIS maximum capacity
RADAR/
AIS
The AIS target count exceeded the maximum
target display count
A
ARCS Security failed
ECDIS
[ARCS] Alert related to ARCS security
B
Arrived at WOL
ECDIS
Approach to the Wheel Over Line
A
Autopilot malfunction
S-JOY/M
JS-9000
AP equipment malfunction
B
Blizzard(Process Error)
Control
section
The control circuit in the radar antenna is
abnormal.
B
Blizzard(SYNC Signal Lost)
Control
section
ASIC for radar detected an error in an
interrupt signal.
B
Blizzard#n-DSP#m(Commu
nication error)
Control
section
Communication error with the DSP
(Blizzard#n - DSP#m)
B
Blizzard#n DSP#m (Load
Failed)
Control
section
The transfer of the DSP program did not
succeed. (Blizzard #n - DSP#m)
B
Blizzard#n High TEMP
Control
section
Blizzard#n temperature rise
B
CCU Fan
Control
section
Drop in CCU fan revolution per speed
B
Change Autopilot steering
mode
TCS
Manual steering prompt alert
B
Chart Shift
ECDIS
ARCS chart shift
B
Chart Shift to WGS84
ECDIS
Chart shift to WGS84 in ARCS chart
B
CIF(Communication error)
Control
section
Communication error between the CPU and
the Companion MPU
B
CMP
RelaySoftware(Communicat
ion error)
Control
section
Communication error between the
Companion MPU relay software and the MFD
B
COG/SOG(invalid)
INS
COG/SOG data validity error
B
COG/SOG(not plausible)
INS
COG/SOG data plausibility error
B
COG/SOG(unavailable)
INS
COG/SOG data not received yet
B
Course difference(heading
deviates from track course)
TCS
Course difference (ship's heading deviates
from track course)
A
CPU Core#n Clock down
Control
section
CPU Core#n clock down
B
CPU Core#n High TEMP
Control
section
CPU Core#n temperature rise
B
CPU Fan
Control
section
The RPS fan revolution per minute has been
decreased.
B
Summary of Contents for ECDIS
Page 2: ......
Page 10: ...Contents 8 ...
Page 40: ...Section 17 Adjusting and Setting up Equipment for Services 17 30 ...
Page 132: ...Section 20 Failures and After Sale Services 20 20 ...
Page 152: ...Section 22 Specifications 22 18 ...
Page 212: ...Appendix B Menu List and Materials B 32 B 1 16 Code Input Password ECDIS CONNING ...
Page 368: ...Appendix B Menu List and Materials B 188 ...
Page 369: ......