www.jouleuk.co.uk | www.joule.ie
24
Direct Horizontal Technical Specification
Capacity
150L
170L
200L
250L
300L
A (mm)
1085
1205
1085
1335
1335
B (mm)
530
530
600
600
600
Heat Up Time
(fr. 15°C to 60°C)
76
96
119
140
166
Weight Empty (kg)
34
37
40
49
56
Weight Full (kg)
184
207
240
299
356
Operating Pressure
3 bar
Max. Water Supply Press.
10 bar
Max Prim. Working Press.
3 bar
X
X
Y
Y
1 Hot Water Draw Off - 1” Female
2 Secondary Return - 1/4” Female
3 T&P Relief Valve - 1/2” Female
4 Immersion Heater - 1 3/4” Female
5 Cold Water Inlet - 1” Female
4
4
2
5
3
1
A
B
Summary of Contents for Cyclone series
Page 52: ...www jouleuk co uk www joule ie 52 48 Direct Indirect Mains Pressure Benchmark Checklist...
Page 53: ...Cyclone Direct Indirect Installation Guide 53 49 Water Storage System Commisioning...
Page 55: ...Cyclone Direct Indirect Installation Guide 55 Notes...
Page 56: ...www jouleuk co uk www joule ie 56 Notes...
Page 57: ...Cyclone Direct Indirect Installation Guide 57...