Electronic Controls
Electrical Controls
Suitable time and temperature controls should be installed to allow the cylinder to operate at it’s
maximum e ciency. All electrical work carried out must comply with IEE Wiring Regulations (BS
3456). Products must also be installed as per the regulations in G3 of the Building Regulations. A
boiler interlock should be in place and is a wiring arrangement where the boiler cannot re unless
there is a demand for hot water generation.
Typical Wiring Diagrams
These diagrams relate only to the components listed. Others may vary in their wiring requirements,
particularly thermostats. Always refer to manufacturers’ instructions which may override the detail
in order to function correctly.
The link must be installed between the adjustable thermostat and the safety cut-out thermostat as
shown above. The working thermostat which controls the temperature of the domestic hot water
is adjustable. A safety cut out is also incorporated within the thermostat and will operate at 85°C ±
3°C. Both thermostats should run in series. To reset the safety cut-out and the motorised valve the
reset button must be pressed in.
JOULE cannot be responsible if alternative wiring plans are used.
Before resetting the safety cut-out or altering the thermostat setting, isolate electrical
supply to the unit before removal of the cover.
Temperature control
clockwise to increase,
counter-clockwise to
decrease
Thermal cut-out
reset under cap
2 Channel Time Clock
DHW Dual Cylinder Stat
Adjustable
Thermostat
Safety High
Limit Stat
Installer Link
DHW Zone Valve
Summary of Contents for Cyclone series
Page 52: ...www jouleuk co uk www joule ie 52 48 Direct Indirect Mains Pressure Benchmark Checklist...
Page 53: ...Cyclone Direct Indirect Installation Guide 53 49 Water Storage System Commisioning...
Page 55: ...Cyclone Direct Indirect Installation Guide 55 Notes...
Page 56: ...www jouleuk co uk www joule ie 56 Notes...
Page 57: ...Cyclone Direct Indirect Installation Guide 57...