Cyclone Direct / Indirect Installation Guide
17
Nominal Capacity (ltr)
100
125
150
170
200
250
300
400
500
Indirect & Solar Vertical
Storage Volume V (ltr)
96
124
147
168
194
247
290
390
495
Standing Loss (kW)
44
52
55
58
78
87
92
102
115
ErP Rating
B
B
B
B
C
C
C
C
C
Nominal Capacity (ltr)
100
125
150
170
200
250
300
400
500
Indirect & Solar Horizontal
Storage Volume V (ltr)
-
-
147
168
194
247
290
-
-
Standing Loss (kW)
-
-
63
69
89
97
104
-
-
ErP Rating
-
-
C
C
C
C
C
-
-
Maximum mains water supply pressure
2.5MPa (25 bar)
Operating pressure/PRV
0.3MPa (3 bar)
Expansion vessel pressure
1.0MPa (10 bar max)
Expansion relief valve setting
0.6MPa (6 bar)
Maximum design pressure
0.4MPa (4 bar)
T&P relief valve setting
0.7MPa/90 °C (7 bar)
Primary coil operating pressure (max)
0.3MPa (3 bar)
Immersion heater rating (a.c. supply only) single phase
3kW 50/60Hz ~
Storage weights (empty and full)
See Specification Tables
Indirect coil ratings
See Specification Tables
Pressure drop across the indirect coils
See Specification Tables
Coil surface area
See Specification Tables
Technical Data
Indirect models in conformance with BS EN 12897:2016
Summary of Contents for Cyclone series
Page 52: ...www jouleuk co uk www joule ie 52 48 Direct Indirect Mains Pressure Benchmark Checklist...
Page 53: ...Cyclone Direct Indirect Installation Guide 53 49 Water Storage System Commisioning...
Page 55: ...Cyclone Direct Indirect Installation Guide 55 Notes...
Page 56: ...www jouleuk co uk www joule ie 56 Notes...
Page 57: ...Cyclone Direct Indirect Installation Guide 57...