![Jøtul C 620 Installation And Operating Instructions Manual Download Page 9](http://html1.mh-extra.com/html/jotul/c-620/c-620_installation-and-operating-instructions-manual_2037613009.webp)
9
ENGLISH
Fig. 3
A
1. Remove the screws (A) that secure the cassette to the pallet.
4.7 Installation
When loosened from the pallet, the cassette is now ready to
be installed in a suitable surround.
If no outside air connection is needed, and there is easy access
in the surround above the cassette, the cassette can ble placed
into the surround. Install the
fl
ue pipe with or without adaptor (
fi
g
4/5), and then install the cassette in the surround (
fi
g 13b+15).
Fig. 4
2
1
1. Pull o
ff
the protective paper from the supplied gasket and
attach it to the bottom of the
fl
ue pipe, folding both inwards
and outwards around the pipe.
2. Insert the
fl
ue pipe into the smoke outlet.
Assemble
fl
ue pipe with adaptor (Ø150)
Fig. 5a
1. Pull o
ff
the protective paper from the supplied gasket and
attach it to the bottom of the adaptor. The gasket should
follow the outer edge.
Fig 5b
4
1
5
3
2
1. Place the adaptor into the smoke outlet.
2. Turn the adaptor until it is
fi
rmly attached in the smoke
outlet.
3. Pull o
ff
the protective paper from the supplied gasket and
attach it to the bottom of the
fl
ue pipe, folding both inwards
and outwars around the pipe.
4. Insert the
fl
ue pipe into the adaptor.
5. Tighten the screws on both sides of the adaptor.
The product can now be installed in the surround, with a narrow
or wide frame (see
fi
g 13b and 15).
Installation with limited access inside the
surround
If there is limited access above the product in the surround
during assembly, the smoke outlet can be installed from inside
the burn chamber. The adaptor is then attached to the
fl
ue pipe
in the surround, and later attached to the burn chamber from
the inside, when the cassette is in place.
Start by removing the ba
ffl
e plate and exhaust de
fl
ector (
see
fi
g 37-39)
.
Summary of Contents for C 620
Page 5: ...5 ENGLISH Fig 1b J tul C620 Combustible wall Non combustible wall Chimney wall Fig 1b...
Page 26: ...26 FRANCAIS Fig 1b J tul C620 Mur combustible Mur ininflammable Mur de chemin e...
Page 44: ...44...
Page 47: ...47 ITALIANO Fig 1b J tul C620 Parete combustibile Muro tagliafuoco Parete del camino...
Page 66: ...66...
Page 69: ...69 ESPA OL Fig 1b J tul C620 Pared de material combustible Muro cortafuegos Pared de chimenea...
Page 87: ...87 EK s s E Y t d K h Y K d d d W Z d D W D d d d Z d D D Y...