3.0 Safety
NB! To guarantee optimal performance and safety, Jøtul
recommends that its stoves are
fi
tted by a quali
fi
ed
installer (see www.jotul.com for a complete list of dealers).
Any modi
fi
cations to the product by the distributor, installer or
consumer may result in the product and safety features not
functioning as intended. The same applies to the installation of
accessories or optional extras not supplied by Jøtul. This may
also be the case if parts that are essential to the functioning and
safety of the
fi
replace have been disassembled or removed.
In all these cases, the manufacturer is not responsible or liable
for the product and the right to make a complaint becomes null
and void.
Keep the door closed during use (the product is not approved
for use with open door
3.1 Fire Prevention Measures
There is a certain element of danger every time you use
your
fi
replace. The following instructions must therefore be
followed:
• The minimum safety distances when installing and using
the
fi
replace are given in
fi
g. 1
. The speci
fi
ed distance to
fl
ammable materials, applies to this stove. The stove must
be installed with a CE approved
fl
ue. The distance of the
fl
ue pipe to combustible materials must also be observed.
• Ensure that furniture and other
fl
ammable materials are not
too close to the
fi
replace. Flammable materials should not
be placed within 1100 mm of the
fi
replace.
• Allow
the
fi
re to burn out. Never extinguish the
fl
ames with
water.
• The
fi
replace becomes hot when lit and may cause burns
if touched.
• Only remove ash when the
fi
replace is cold. Ash can contain
hot embers and should therefore be placed in a non-
fl
ammable container.
• Ash should be placed outdoors or be emptied in a place
where it will not present a potential
fi
re hazard.
In case of chimney
fi
re:
• Close all hatches and vents.
• Keep
the
fi
rebox door closed.
• Call
the
fi
re service.
• Before use after a
fi
re an expert must check the
fi
replace
and the chimney in order to ensure that it is fully functional
3.2 Floor
Foundation
You need to make sure the foundation is suitable for a
fi
replace.
See
“2.0 Technical Data”
for speci
fi
ed weight.
We recommend the removal of any
fl
ooring that is not attached
to the foundation (“
fl
oating
fl
oors”) beneath the installation.
Jøtul recommends that any
fl
ooring made of combustible
material, such as linoleum, carpets, etc. should be removed
from under the
fl
oor plate.
Requirements for protection of wooden
fl
ooring beneath the
fi
replace
The
fl
oor beneath the
fi
replace must be protected by a sheet
of metal or other non-in
fl
ammable material. The recommended
minimum thickness is 0.9 mm. The
fl
oor plate must comply
with national laws and regulations. Distance between
fl
oor and
cassette must be a minimum of 365 mm (see
fi
g. 1)
Requirements for protection of
in
fl
ammable
fl
oors in front of the
fi
replace
The
fl
oor in front of the
fi
replace must be protected by a sheet
of metal or other non-in
fl
ammable material. The recommended
minimum thickness is 0.9 mm. The
fl
oor plate must comply with
national laws and regulations.
Contact your local building authorities regarding restrictions and
installation requirements.
3.3 Walls
• The product should be placed so that it is possible to clean
the stove,
fl
ue pipe and chimney outlet.
• Make sure furniture and other combustible materials do not
get too close to the stove, see safety distances in
fi
g.1. This
will also prevent them from drying out.
Distance to walls made of combustible material - see
fi
g. 1a
The stove must be installed with a CE approved
fl
ue pipe.
European, national and local regulations must be observed
with regard to the safety distances for stoves as well as
fl
ue
pipes and chimneys. Please note that CE marked
fl
ue pipes
may have a greater distance to combustible materials, than
the stove.
Distance to combustible wall protected by insulation
Distance to combustible wall protected by
fi
rewall/insulation:
See
fi
g. 1.
3.4 Ceiling
The
fi
replace can be
fi
tted with the top edge of the hot air
opening of the surround at least 480 mm below a ceiling of
in
fl
ammable material. See Fig. 1b. Ensure there is
adequate ventilation in the top of the cowl – e.g. a gap under
the ceiling.
Summary of Contents for C 620
Page 5: ...5 ENGLISH Fig 1b J tul C620 Combustible wall Non combustible wall Chimney wall Fig 1b...
Page 26: ...26 FRANCAIS Fig 1b J tul C620 Mur combustible Mur ininflammable Mur de chemin e...
Page 44: ...44...
Page 47: ...47 ITALIANO Fig 1b J tul C620 Parete combustibile Muro tagliafuoco Parete del camino...
Page 66: ...66...
Page 69: ...69 ESPA OL Fig 1b J tul C620 Pared de material combustible Muro cortafuegos Pared de chimenea...
Page 87: ...87 EK s s E Y t d K h Y K d d d W Z d D W D d d d Z d D D Y...