EG0LD-1000 Electronic Grease Level Detector

                                              

    

                                         

 

Installation and Operating Procedures 
__________________________________________________________________________________________ 

 

 

Page 9 

 

 
EGOLD-1000 System

 

 

 
3.0 EGOLD-1000 Controls and Indicators 

 

3.1 Control Unit 

 
The face of Control Unit has two (2) momentary push button controls: 
 

Calibrate

 Button 

-This button is pressed to initiate a calibration procedure. 

 

Alarm Reset

 Button  -This button is pressed to turn off the level alarm buzzer.  

 
 
The face of the Control Unit has the following LED indicators: 
 

Power

 LED 

 

-When ON this LED indicates that the Control Unit has power applied. 

 

Operating

 LED 

-When ON this LED indicates that the EGOLD-1000 Electronic Grease Level 
 Detector system is operating properly in the grease level detection mode. 

 

Calibration

 LED 

-When ON this LED indicates that the EGOLD-1000 Electronic Grease Level 
 Detector system is in the grease level calibration mode. 

 

Level 

LEDs 

 

-A set of 5 vertical LED indicators displays the current level of grease being 
 detected in the interceptor tank. Each LED indicator represents approximately 
 one fifth (1/5) of the maximum grease level volume.  

 

-The bottom three (3) 

Green

 LEDs indicate the grease volume is below the 

 level required for grease interceptor tank cleaning. Note: The three (3) 

Green 

 LED indicators are also used during the system calibration.  

 

-The 

Yellow

 LED indicates the grease volume is approaching the level 

 required for cleaning the grease interceptor tank.   

 
 

 

 

-The 

Red

 LED indicates the grease volume has reached the level requiring the 

 grease interceptor tank to be cleaned.   

 
 
Figure 3-1 illustrates the face of the Control Unit.   

Summary of Contents for EGOLD-1000

Page 1: ...000 Electronic Grease Level Detector Installation and Operating Procedures Josam Company 2501 South Front Street Philadelphia PA 19148 215 339 5370 WARNING Cancer and Reproductive Harm www p65warnings...

Page 2: ...EGOLD 1000 CONTROLS AND INDICATORS 9 4 0 EGOLD 1000 CALIBRATION 11 5 0 EGOLD 1000 OPERATION 13 6 0 EGOLD 1000 MAINTENANCE 15 Figures FIGURE 1 1 ILLUSTRATES THE E LECTRONIC GREASE LEVEL DETECTION SYST...

Page 3: ...nted Control Unit and the Tank Probe assembly The Control Unit GLS housing connectors control switches and indicators are water resistant for splash or spray conditions The Tank Probe assembly is a se...

Page 4: ...EG0LD 1000 Electronic Grease Level Detector Installation and Operating Procedures __________________________________________________________________________________________ Page 4 Figure 1 1 MODEM...

Page 5: ...20 inches will require Tank Probe assembly part number MA47 18 Note For inside tank wall heights greater than 22 inches consult JOSAM for the proper Tank Probe assembly part number Prior to mounting t...

Page 6: ...rceptor and within 5 feet of an 115VAC wall outlet 2 Place the Control Unit on the wall and mark the two 2 mounting hole locations Drill 3 16 holes to accept the mounting hardware 3 Use the mounting h...

Page 7: ...th the 20 screw and wing nut provided Bracket B should be free to slide up and down on bracket A Attach the probe to the underside of bracket A with the 20 screw provided Slide the probe and bracket B...

Page 8: ...el Detector Installation and Operating Procedures __________________________________________________________________________________________ Page 8 Figure 2 1 STATIC WATER LEVEL OUTLET BRACKET A BRACK...

Page 9: ...stem is operating properly in the grease level detection mode Calibration LED When ON this LED indicates that the EGOLD 1000 Electronic Grease Level Detector system is in the grease level calibration...

Page 10: ...or Installation and Operating Procedures __________________________________________________________________________________________ Page 10 2 5mm POWER JACK CENTER POSITIVE MOUNT USING 8 HARDWARE PROV...

Page 11: ...eptor tank wall that is approximately 1 3 of the distance from the bottom of the outlet pipe to the bottom of the tank Note When grease fills the interceptor tank down to this level the alarm will be...

Page 12: ...interceptor tank with water until water flows out of the interceptor tank outlet pipe 10 Press the Cal Set Button on the Control Unit The two 2 Green LEDs will begin flashing After several minutes the...

Page 13: ...he Yellow LED indicates the grease volume is approaching the level required for cleaning the grease interceptor tank The Red LED indicates the grease volume has reached the level requiring the grease...

Page 14: ...operating errors as follows The Operating LED will be OFF The Red Level LED will be flashing The audible Alarm will sound intermittently short beeps once every ten seconds System errors include Loss o...

Page 15: ...be cleaned every time the grease is emptied from the interceptor tank As a minimum the tank probe should be cleaned every 6 months Tank probe cleaning can be accomplished by wiping the probe with a s...

Page 16: ...onic Grease Level Detector Installation and Operating Procedures __________________________________________________________________________________________ Page 16 Appendix I Tank Probe Assembly Mount...

Page 17: ...00 Electronic Grease Level Detector Installation and Operating Procedures __________________________________________________________________________________________ Page 17 Appendix II Optional Alarm...

Page 18: ...hat is within 15 feet of the Control Unit within 5 feet of an 115VAC wall outlet and within 5 feet of a telephone jack to place the Modem Unit provided 2 Plug the jack connector of the modem cable pro...

Reviews: