EG0LD-1000 Electronic Grease Level Detector
Installation and Operating Procedures
__________________________________________________________________________________________
Page 12
8)
The bottom two (2)
Green
LEDs should turn ON. Then press the
Cal Set
Button on the Control
Unit. The two (2)
Green
LEDs will begin flashing and then turn OFF after several minutes (the
horn will also beep). The
CAL
LED will continue flashing indicating the Control Unit is still in
the calibration mode.
9) Fill the interceptor tank with water until water flows out of the interceptor tank outlet pipe.
10) Press the
Cal Set
Button on the Control Unit. The two (2)
Green
LEDs will begin flashing. After
several minutes the
CAL
LED and the two (2)
Green
LEDs will turn OFF (the horn will also
beep). The
Run
LED will then turn ON indicating that calibration was successfully complete and
the unit is now operating in the grease level detection mode.
Note: The
Red
Level LED will turn ON and the
CAL
LED will continue flashing indicating the
system calibration was not successful. Repeat the calibration procedure a second time. Contact
JOSAM for technical support if system calibration is not successful the second time.