EG0LD-1000 Electronic Grease Level Detector
Installation and Operating Procedures
__________________________________________________________________________________________
Page 13
5.0 EGOLD-1000 Operation
Once the EGOLD-1000 Electronic Grease Level Detector system is calibrated, operation is fully
automatic and requires no operator interaction.
Normal Operation
The EGOLD-1000 Electronic Grease Level Detector system operates as follows:
The interceptor grease level is continuously monitored.
The
Level Indicating LEDs
provide an indication of the current level.
-
The bottom three (3)
Green
LEDs indicate the grease volume is below the
level required for grease interceptor tank cleaning.
-
The
Yellow
LED indicates the grease volume is approaching the level
required for cleaning the grease interceptor tank.
-
The
Red
LED indicates the grease volume has reached the level requiring the
grease interceptor tank to be cleaned.
The audible Alarm will sound once the
Red
LED indicates the grease volume has reached the
level requiring the grease interceptor tank to be cleaned
Note: If installed, the optional Alarm will also sound at this time.
Pressing the Alarm Reset Button on the Control Unit can silence the Alarms.
Note: The audible alarm will again sound after several minutes if the grease volume still at
the level requiring the tank to be cleaned.
Power should be removed from the Control Unit (unplug power module into the wall socket)
when cleaning the grease interceptor tank.
Note: The EGOLD-1000 Electronic Grease Level Detector system will maintain calibration
when unpowered.