7.
Lower the stainless steel flue pipe all the way in the special space
on the exchanger, operating from the fume exhaust or, if possible,
from the outside, forcing it down with hands or using a curved iron
(
F
ig
. 10
) to hermetically close the fume passage.
To operate from the fumes exhaust, it is necessary to remove
the deflector from the top section of the fireplace. To remove
the fume deflector, lift the deflector to unhook it from the support
pins and move it towards the door, afterwards remove the
fume cap (see
CHAP.08.4 - ROUTINE MAINTENANCE
).
Repeat these operations in the reverse order to reposition it.
8.
If possible, pad with rock wool between the existing chimney
flue and the stainless steel pipe to prevent a return of the flue
gases and stop soot from falling and excluding the risk of a fire
or, where possible seal with fire-proof cementitious material.
9.
If ducting is provided for, knock out the precut sheets on the hot air outlets with a hammer (
F
ig
. 11
and
12
). The air connections can also
be applied with the fireplace fitted, by removing the damper.
10.
Insert the connection and pipe in the space and turn to secure the connection (
F
ig
. 13
and
14
).
N.B. It is advisable to try fitting the connections before inserting the fireplace.