ENGLISH
For the hot air recycle into the room, it is possible to
choose the following options:
1) When it is not possible to realize an opening for
hot air recycle into the cladding, it is useful to take
the coverings on the sides apart, by screwing off the
screw: in this case the hot air fan will recycle the hot
air into the room from these openings (
F
ig
. 5-6).
2) Realize an opening of about 450 cm
2
for air
recycle directly into the cladding of the fireplace,
without taking apart the two side coverings on the
insert.
b) Combustion air intake and hot air recycle
into the room.
Realize a combustion air intake of about 450 cm
2
connected with the outside in the room of the
installation. Then you have to take apart the
central opening (b) (
F
ig
. 5)
(it is necessary to
screw off the screw and to remove the combustion
air regulation lever). When the central covering is
removed, you have to reassemble the combustion
air regulation lever (
F
ig
. 7-8).
For the hot air recycle into the room, it is possible to
choose the following options:
1) When it is not possible to realize an opening for
hot air recycle into the cladding, it is useful to take
the coverings on the sides apart, by screwing off the
screw: in this case the hot air fan will recycle the hot
air into the room from these openings (
F
ig
. 9).
2) Realize an opening of about 450 cm
2
for air
recycle directly into the cladding of the fireplace,
without taking apart the two side coverings on the
insert.
F
ig
. 8
F
ig
. 5
F
ig
. 6
F
ig
. 7
F
ig
. 9
a
a
b
c