ENGLISH
MINIMAL SECTION SIZES FOR CONVECTION AIR INLETS AND
OUTLETS
In
F
ig
. 3
are shown the minimal section sizes suitable for convection
air Inlets and Outlets and applicable to all installation types available:
A
Min. Convection Air Inlet:
450 cm
2
B
Min. Convection Air Outlet:
450 cm
2
C
Forced convection air outlet Ø:
2xØ100 mm
SAFETY DISTANCES FROM SURROUNDING FLAMMABLE
MATERIALS
In
F
ig
. 2
are shown the safety distances from surrounding flammable
materials applicable to all installation types available:
1. Flammable Wall
2. Flammable floor
3. Flammable ceiling
4. Fireplace cladding in not flammable material.
Installation distances from flammable materials
A
Minimum air distance from inflammable side wall:
400 mm
B
Minimum air distance from inflammable rear wall:
150 mm
C
Minimum air distance from inflammable ceiling:
1000 mm
D
Minimum air distance from flammable floors:
400 mm
R
Frontal air distance from inflammable material:
1500 mm
The cladding of the fireplace must be done
by not flammable material.
WARNING
If the product is installed on a flammable
material, it is necessary to provide a “floor-saver” plate
made of not flammable material
WARNING
A
B
F
ig
. 3
C
F
ig
. 2
R
A
B
1
2
3
C
4
4
D
25