Access Control Module
iSTAR Ultra Installation and Configuration Guide
5–9
Wiegand Connections
J16, J25, J31, J78, J79, J80, J22, J28
Direct Wiegand signaling read head connections are shown in Figure 5-7 on
Figure 5-7:
Wiegand Readers
The data line maximum lengths are:
18 AWG - 500 feet
20 AWG - 300 feet
22 or 24 AWG - 200 feet
Table 5-1:
Wiegand Port Pinouts
Wiegand Port
Pin Number
Signal/Function
1
Power +12 Vdc
2
GND - PWR Return
3
Data 0 - Wiegand Input
4
Data 1 - Wiegand Input
5
Red LED - active low
6
Yellow LED - active low
7
Green LED -active low
8
Beeper - active low