SECTION VIII: TYPICAL WIRING DIAGRAMS
FIGURE 10:
Connection Wiring Diagram
208/230-3-60
THREE PHASE
COOLING UNIT WITH OR WITHOUT
ELECTRIC HEAT
CAUTION - OPEN ALL DISCONNECTS
BEFORE SERVICING THIS UNIT
BLU 29
RED 30
WHT 25
GRN 24
Y
R
G
C
THERMOSTAT
USE COPPER
CONDUCTORS
ONLY
YEL 20
GRN 4
(LOW)
(LOW/MED)
(MED)
(MED/HIGH)
(HIGH)
C
L
G
N
1
2
3
4
5
1
2
3
4
HI PRESS
LOW
VOLTAGE
BOX
W1
(COOLING SPEED)
(HEATING SPEED)
(CONTINUOUS FAN)
BLK
YEL
BLU
BLK/WHT 12
BRN/WHT 13
PUR 1
RED 9
OD FAN
MOTOR
POWER SUPPLY
208/230-3-60
BLK 6
BLK 5
COM
PRIMARY
24V SEC
75 VA
208V
230V
COMPR
L1
L3
L2
L1
T1
T2
L2
CAPACITOR
RED 7
GRN
PUR 2
YEL 18
GRN 21
LINE VOLTAGE
FIELD INSTALLED POWER
LOW VOLTAGE
FIELD INSTALLED CONTROL
5
4
3
2
6
1
BLK
BRN
GRN 10
RED
BLOWER
MOTOR
SHARED TAP
SEE NOTE 6
XFMR
BLU 23
5
4
3
2
6
1
BLU 27
YEL 19
3A FUSE
WHT 32
WHT 26
BRN 28
W2
FEMALE CONNECTOR
FOR 6HK HEATER KIT
OR SEQUENCER
SECOND STAGE RELAY
OR SEQUENCER
FIRST STAGE RELAY
24V COMMON
FOR WIRING WITH ELECTRIC HEATERS
SEE SCHEMATIC ON HEATER ACCESSORY.
RED 33
CONNECTION WIRING DIAGRAM
INDOOR BLOWER 60 SECOND OFF
DELAY FOR BOTH HEAT & COOL MODES.
GND
LUG
CRANKCASE
HEATER
GRN
TEMPERATURE
SWITCH
OPTIONAL CRANKCASE HEATER
BLK
T3
L3
BLK
BLK
CONTACTOR
CONTACTOR
CONTACTOR
1. ALL FIELD WIRING TO BE ACCOMPLISHED FOLLOWING CITY, LOCAL AND/OR
NATIONAL CODES IN EFFECT AT THE TIME OF INSTALLATION OF THE UNIT.
2. CAUTION : LABEL ALL WIRES PRIOR TO DISCONNECTION WHEN SERVICING
CONTROLS. WIRING ERRORS CAN CAUSE IMPROPER AND DANGEROUS
OPERATION. IF ANY OF THE WIRING, AS SUPPLIED WITH THE UNIT, MUST
BE REMOVED, IT MUST BE REPLACED WITH TYPE 105 C. 600 VOLT
WIRE OR EQUIVALENT CLEARLY RENUMBERED FOR IDENTIFICATION.
VERIFY PROPER OPERATION AFTER SERVICING.
3. FACTORY WIRED FOR 230 VOLT THREE-PHASE SUPPLY POWER. FOR 208 VOLT,
MOVE BLACK WIRES FROM THE 230 TO THE 208 VOLT TAP ON THE TRANSFORMER.
4. MOTORS ARE INHERENTLY PROTECTED.
5. SEE UNIT NAMEPLATE FOR MAXIMUM FUSE AND/OR CIRCUIT BREAKER SIZE
AND MINIMUM CIRCUIT AMPACITY.
6. BLOWER MOTOR SPEED CONNECTIONS SHOWN ARE TYPICAL, BUT
MAY VARY BY MODEL AND APPLICATION. SEE INSTALLATION MANUAL
FOR PROPER SPEED TAP INFORMATION FOR EACH APPLICATION TO OBTAIN
APPROX. 400 CFM/TON IN COOLING.
7. IF ELECTRIC HEAT IS INSTALLED, SELECT A HEATING BLOWER SPEED THAT
DELIVERS SUFFICIENT AIRFLOW TO SUIT THE WATTAGE OF ELECTRIC HEAT
INSTALLED. SEE TABLE IN INSTALLATION MANUAL.
NOTES:
THIS UNIT IS WIRED
FOR THREE-PHASE POWER.
DO NOT CONNECT TO
A SINGLE-PHASE SUPPLY.
NOTICE
BLU 22
CONTACTOR
COIL
YEL 18
BLU 15
5146413-UWD-B-0915