Installation
• The set-up of the electrical installation is
arranged so that the appliance can be isolated
from the mains with a minimum 3 mm all-pole
contact separation.
Suitable isolation devices include, for
example, circuit breakers, fuses (screw type
fuses are to be removed from the holder),
RCDs and contactors.
• Anti-shock protection must be provided by
the installation.
• The built-in unit must meet the stability
requirements of DIN 68930.
• Built-in cookers and cooking surfaces are
equipped with special attachment systems.
For safety reasons, they must only be
combined with appliances from the same
manufacturer.
The use of heat protection strips is prohibited
for cookers and ovens with Pyrolytic Cleaning, if
the recess has a rear wall and closed ground-
level compartment.
However installation is possible with a ground-
level compartment that has been shortened by
at least 20 mm and which has base ventilation of
the same cross-section.