SECTION 6 – GENERAL SPECIFICATIONS & OPERATOR MAINTENANCE
6-26
– JLG Lift –
31210162
Lifting Chains
Lube Points - 4 chains
Capacity: A/R
Lube - C (See Table 6-6)
Interval - After the first 50 hours of operation and every 125
hours of operation (or every 30 days) thereafter.
Lubricant can be applied manually with a brush or by spraying.
Apply lubricant longitudinally and transversally for the lubricant
to reach the joints between the plates.
Table 6-10. Recommended Viscosity Grade
TEMPERATURE
ISO VISCOSITY GRADE
-15°C to 0°C (5°F to 32°F)
15 to 32 mm
²
/s (cSt)
0°C to 50°C (32°F to 122°F)
46 to 150 mm
²
/s (cSt)