Electrical Connections
Unit operates on 115V AC, 60 Hz. current.
10.93 amps current draw (3.93 amps for lift, 7 amps for outlet).
Opening the electrical box exposes terminals for field connections.
Unit is shipped with internal wiring complete.
Wire to connect unit to power supply should be furnished by installer.
Connections should be made in accordance with wiring diagram,
and wiring should comply with national and local electrical codes.
An appropriate disconnect device shall be provided as part of the building
installation. All operating switches should be “off” before power is connected.
Caution: Make sure electrical supply has been disconnected before
attempting to connect Scissor Lift to electricity.
Scissor Lift should be operated and checked prior to installing projector and/or
optional ceiling closure.
Low Voltage Control Switch shown on Page 2
comes with 22.8 m of non-
plenum rated cable and should be plugged in to Control Panel on top frame of lift
for control of the "Up" and "Show" positions.
Momentary Key Switch shown on Page 2
comes with 22.8 m of cable and
should be plugged in to Control Panel on top frame of lift for control of the
"Service" position.
If you encounter any difficulties installing or servicing your Scissor Lift SLX, call your
dealer or Draper, Inc. in Spiceland, Indiana, 765-987-7999, or fax 765-987-7142.
Caution:
ImPOrtAnt SAfety InStrUCtIOnS
Read all instructions completely before proceeding.
WARNING/AVERTISSEMENT
RISK OF ELECTRIC SHOCK. DO NOT OPEN
RISQUE DE CHOC ELECTRIQUE. NE PAS OUVRIR.
DAnGer: to reduce risk of shock:
1
Always disconnect power from lift before cleaning.
WARNING–To reduce risk of burns, fires, electric shock or injuries to persons:
2
Disconnect power from lift before putting on or taking off parts.
3
Use this lift only for its intended use as described in these instructions.
Do not use attachments not recommended by the manufacturer.
4
Never operate this lift if it has a damaged cord or plug. If it is not working
properly, call your dealer or the manufacturer for assistance/repair.
5
Keep cords away from heated surfaces.
6
Never operate lift with air opening blocked. Keep the air openings free of lint,
hair, and the like.
7
Never drop or insert any object into any opening.
8
Do not use outdoors.
9
Route cords and cables as shown in the instructions.
10
WARNING:
Rick of Electric Shock—
connect this product to a properly grounded electrical supply.
ImPOrtAnt InStALLAtIOn/OPerAtInG InStrUCtIOnS
WARNING: To prevent injury, this apparatus must be securely attached to
the building structure in accordance with the instructions.
11
Test lift prior to installation.
Please Note: Packaging must be removed from lift before testing.
12
Follow instructions carefully. Installation contrary to instructions invalidates warranty.
13
Do not obstruct operation of Scissor Lift SLX with fingers or any object.
Serious injury or damage could result.
14
Lift is intended for use with product weighing not more than 350 pounds.
15
Scissor Lift SLX is designed to accommodate ceiling suspended equipment.
equipment should not be allowed to rest on optional ceiling closure
during operation (refer to section titled “Installing Projector”).
16
Entire bottom of unit must be unobstructed to permit proper operation.
Sufficient clearance must be allowed below projector or optional ceiling closure:
10' for Model SLX10, 14' for Model SLX14, etc.
17
Unit must be installed level (use a carpenter’s level).
18
Unit operates on 115V AC 60 Hz. current. 10.93 amps current draw (3.93
amps for lift, 7 amps for outlet).
19
Verify the show position when testing lift. Make required changes by referring
to adjustment instructions on page 4 of this document.
20
The maintenance/service factory limit setting must not be adjusted to a lower
position than the preset factory limit setting. In addition, Draper does not
recommend setting show position at the maintenance/service position—for
example, if you wish to have 8' show position, order a lift with at least a 10'
maintenance position.
21
When the Scissor Lift SLX is to be installed in “other space used for
environmental air” the optional environmental air space housing must
be installed per instructions to isolate the lift from the “other space
used for environmental air.”
22
When Scissor Lift SLX is
nOt
installed in environmental air space housing
and optional ceiling closure, the
ALTERNATE
wiring for up limit switch may
be used
(see Alternate Wiring schematic on page 5).
CAUTION: Before servicing unit, disconnect hardwired control and any
remote control.
Note:
Unit has been thoroughly inspected and tested at factory and found to be
operating properly prior to shipment.
Planning
1
Based on screen location and projector specifications, determine proper
position for projector installation.
2
Confirm that there is adequate space for installation and operation.
Minimum clearance above ceiling level varies according to Scissor Lift model,
plus height of projector, optional mounting bracket, optional ceiling closure,
and optional Environmental Air Space Housing.
3
Arrange to provide service access to the unit.
4
Maximum lifting capacity is 350 kg.
As Soon As Scissor Lift Arrives
1
Open carton and inspect for damage.
2
Locate the following parts:
A. the unit itself
B. Controls
C. Optional equipment:
I. Environmental Air Space Housing,
II. Universal Projector Mount,
III. Closure Panel or Ceiling Finish Kit
(all ship in separate cartons).
3
Test lift prior to installation.
Please Note: Packaging must be removed from lift before testing.
Caution:
Beware of pinch points
Caution: Beware
of pinch points