SECTION 3 - CHASSIS & TURNTABLE
31215031
3-95
630
12
376
2-8-1
Access error EEPROM memory (delete).
Sections could not be erased.
Threshold for error detection is an internal ECU
threshold.
There is no healing possible for the error. In
every new initialization phase, the debounce
level is set to zero.
If not programmed, EEPROM is defect --> ECU is
defect, reprogram ECU and if
necessary replace it.
630
12
377
2-8-1
Access error EEPROM memory (read).
Minimum three blocks could not be readed,
EEPROM has checksum error.
Threshold for error detection is an internal ECU
threshold.
There is no healing possible for the error. In
every new initialization phase, the
debounce level is set to zero.
If not programmed, EEPROM is defect -->ECU is
defect, reprogram ECU and if necessary replace
it.
630
12
378
2-8-1
Access error EEPROM memory (write).
Block could not be written for minimum three
times.
Threshold for error detection is an internal ECU
threshold.
If not programmed, EEPROM is defect --> ECU is
defect, reprogram ECU and if
necessary replace it.
639
14
84
2-7-1
CAN-Bus 0: "BusOff-Status".
Warning and limp home speed gets activated.
Threshold for error detection is an internal ECU
threshold.
Bus Off-bit for CAN A mode is set.
Check wiring of CAN bus and if necessary, repair
it.
Check cable connection and if necessary, repair
or replace it.
Check resistance in CAN lines (120 Ohm).
651
5
568
154
Injector 1 (in firing order): Interruption of
electric connection.
Interruption of electronic connection Injector
cylinder 1.
Check wiring harness, injectors and if necessary
repair or replace it.
Threshold for error detection is an internal ECU
threshold.
651
3
580
154
Injector 1 (in firing order): Short circuit.
Injector cylinder 1:
Wiring harness, cable break or short circuit.
Check wiring harness, injectors and if necessary
repair/replace it.
Use SerDia Injector test for diagnosis.
Threshold for error detection is an internal ECU
threshold.
652
5
569
155
Injector 2 (in firing order): Interruption of
electric connection.
Interruption of electronic connection Injector
cylinder 2.
Check wiring harness, injectors and if necessary
repair or replace it.
Threshold for error detection is an internal ECU
threshold.
652
3
581
155
Injector 2 (in firing order): Short circuit.
Injector cylinder 2:
Wiring harness, cable break or short circuit.
Check wiring harness, injectors and if necessary
repair/replace it.
Use SerDia Injector test for diagnosis.
Threshold for error detection is an internal ECU
threshold.
653
5
570
156
Injector 3 (in firing order): Interruption of
electric connection.
Interruption of electronic connection Injector
cylinder 3.
Check wiring harness, injectors and if necessary
repair or replace it.
Threshold for error detection is an internal ECU
threshold.
Table 3-11. Engine Fault Codes (Deutz Engine)
SPN
FMI
Deutz
Code
Blink
Code
Error Description
Possible Reasons For Error
Take Action For Repair (TAFR)
Go