SECTION 3 - CHASSIS & TURNTABLE
3-90
31215031
51
3
1227
5-9-4
EGR-Valve (2.9;3.6) or Throttle-Valve
(4.1;6.1;7.8); short circuit to battery.
Short-Circuit to battery on component wiring.
Threshold for error detection is an internal ECU
threshold.
Check wiring, component, ECU
Check repair with SerDia 2010 use case.
51
4
1228
5-9-4
EGR-Valve (2.9;3.6) or Throttle-Valve
(4.1;6.1;7.8); short circuit to ground.
Short-Circuit to ground on component wiring.
Threshold for error detection is an internal ECU
threshold.
Check wiring, component, ECU
Check repair with SerDia 2010 use case.
51
4
1229
5-9-4
EGR-Valve (2.9;3.6) or Throttle-Valve
(4.1;6.1;7.8); short circuit to ground.
Short-Circuit to ground on component.
Threshold for error detection is an internal ECU
threshold.
Check wiring, component, ECU
Check repair with SerDia 2010 use case.
51
6
1230
5-9-4
Actuator error EGR-Valve (2.9;3.6) or Throt-
tle-Valve (4.1;6.1;7.8); Overload by short-
circuit.
Short Circuit over Load.
Threshold for error detection is an internal ECU
threshold.
Check wiring, component.
51
11
1231
5-9-4
Power stage over temperature due to high
current.
Temperature dependent Over Current.
Threshold for error detection is an internal ECU
threshold.
Check wiring, component.
51
4
1232
5-9-4
Actuator AGR valve (2.9;3.6) throttle valve
(4.1;6.1;7.8); Voltage below threshold.
Monitoring for CY146 Under Voltage.
Threshold for error detection is an internal ECU
threshold.
Check wiring, component.
91
3
935
2-2-6
Sensor error accelerator pedal.
signal range check high.
Sensor defect.
Short cut to battery or open loop.
Check cabling, check accelerator pedal sensor
and if necessary replace it, check
connection cable and if necessary repair or
replace it.
If the signal is below the applicatable threshold
APP_uRaw1SRCHigh_C, the signal
range violation is reset after the healing
debouncing.
91
4
940
2-2-6
Sensor error accelerator pedal.
Signal is below the range.
Sensor defect.
Short circuit to Ground.
Check cabling, check accelerator pedal sensor
and if necessary replace it, check
connection cable and if necessary repair or
replace it.
If the signal exceeds the applicable table
threshold APP_uRaw1SRCLow_C, the signal
range violation is reset after the healing.
91
11
976
2-2-6
Plausibility error between APP1 and APP2 or
APP1 and idle switch.
Measured voltage of accelerator pedal 1 is out of
plausible range.
Threshold for error detection is an internal ECU
threshold.
Check cabling, check accelerator pedal and
pedal sensor and if necessary replace it,
check connection cable and if necessary repair
or replace it.
When the PWM period APP_tiPWMPer is in
between APP_tiSRCLoPWMPer_C and
APP_tiSRCHiPWMPer_C .
94
3
472
2-1-6
Sensor error low fuel pressure, signal range
check high.
Cable break or short circuit, sensor defective,
connection cable is damaged.
Short cut to battery or open loop.
Check cabling.
Check connection cable and if necessary repair
or replace it.
If sensor is not working, check sensor and if nec-
essary replace it.
Table 3-11. Engine Fault Codes (Deutz Engine)
SPN
FMI
Deutz
Code
Blink
Code
Error Description
Possible Reasons For Error
Take Action For Repair (TAFR)