SECTION 3 - CHASSIS & TURNTABLE
3-92
31215031
102
2
88
2-2-3
Charged air pressure above warning thresh-
old.
Charged air cooler pressure above threshold.
Check waste gate system if necessary replace
TC.
Check CAC, if all channels are clean, check
charge air piping.
If an error occurs, always check the delta P sen-
sor and the Venturi tube for damage or
contamination, because problems at this point
can lead to this result error.
102
2
89
2-2-3
Charged air pressure above shut off thresh-
old.
Charge air pressure above shut off threshold.
Check waste gate system if necessary, replace
TC, check CAC if all channels are clean,
check charge air piping if necessary.
If an error occurs, always check the delta P sen-
sor and the Venturi tube for damage or
contamination, because problems at this point
can lead to this result error.
102
3
776
2-2-3
Pressure downstream charge air cooler,
short circuit to battery or open load.
The Sensor Voltage is above the Threshold.
Check cabling, if charge air pressure/tempera-
ture sensor is not working, check sensor
and if necessary replace it, check connection
cable and if necessary repair or replace it.
102
4
777
2-2-3
Pressure downstream charge air cooler,
short circuit to ground.
The Sensor Voltage is below the Threshold.
Check cabling, if charge air pressure/tempera-
ture sensor is not working, check sensor
and if necessary replace it, check connection
cable and if necessary repair or replace it.
105
3
994
1-2-8
Electrical error charged air temperature.
Signal range check high (SRC).
Short circuit to battery.
sensor voltage > limit.
The sensor raw signal Air_uRawTCACDs (volt-
age) > Air_SRCTCACDs.uMin_C.
Check CAC-sensor and if necessary replace it,
check connection cable and if
necessary repair or replace it.
105
4
995
1-2-8
Electrical error charged air temperature.
Signal range check low.
Short circuit to ground or open load.
sensor voltage < limit.
The sensor raw signal Air_uRawTCACDs (volt-
age) is below Air_SRCTCACDs.uMin_C.
Check CAC-sensor and if necessary replace it,
check connection cable and if
necessary repair or replace it.
105
0
996
2-3-3
Charged air cooler temperature. System
reaction initiated.
High charged air cooler temperature. Warn-
ing threshold exceeded.
Charge air temperature (downstream) over
warning threshold.
Check CAC system and clean it. Check fan func-
tionality.
Check cooling performance with temperature
measurement.
!! If an error occurs, always check the delta P sen-
sor and the Venturi tube for damage
or contamination because problems at this
point can lead to this result error.!!
105
0
997
2-3-3
High charged air cooler temperature.
Shut off threshold exceeded.
Charge air temperature (downstream) over the
shut off threshold.
Check CAC system and clean it. Check fan func-
tionality. Check cooling performance
with temperature measurement.
!! If an error occurs, always check the delta P sen-
sor and the Venturi tube for damage
or contamination because problems at this
point can lead to this result error.!!
Table 3-11. Engine Fault Codes (Deutz Engine)
SPN
FMI
Deutz
Code
Blink
Code
Error Description
Possible Reasons For Error
Take Action For Repair (TAFR)
Go