SECTION 3 - TROUBLESHOOTING
3-2
– JLG Sizzor –
3120768
Table 3-1. Platform Assembly Troubleshooting
TROUBLE
PROBABLE CAUSE
REMEDY
PLATFORM ELEVATION SYSTEM
No response to control switch
Enable switch not activated
Activate enable switch
Function not activated within 3 seconds after
enable switch was depressed
Reactivate enable switch
Enable switch not functioning properly
Replace enable switch circuit card
Lift control switch inoperative
Replace control switch
Hydraulic oil system low
Replenish oil system necessary
Restricted or broken supply line on valve or pump
Clean, repair or replace as necessary
Control valve not functioning properly
Repair or replace valve
Lift cylinder not functioning properly
Repair or replace lift cylinder
Hydraulic pump not functioning properly
Check Sevcon control contactors for proper func-
tioning
Low battery voltage
Check voltage and charge batteries or replace
batteries as necessary
Platform will not raise
Enable switch not activated
Activate enable switch
Function not activated within 3 seconds after
enable switch was depressed
Reactivate enable switch
Enable switch not functioning properly
Replace enable switch circuit card
Load capacity exceeded. (Personnel and/or
equipment on platform)
Reduce load to recommended capacity
Hydraulic oil system low
Replenish oil as necessary
Restricted or broken oil line or fitting
Clean, repair or replace as necessary
Control valve not functioning properly
Repair or replace valve
Lift cylinder not functioning properly
Repair or replace lift cylinder
Motor/Pump does not respond when lift control
switch is moved to the up position
Refer to the electrical schematic and/or electrical
system troubleshooting chart
No electrical signal being sent to lift up control
valve cartridge
Refer to the electrical schematic and/or electrical
system troubleshooting chart
Pressure set to low on pump
Check pressure and reset as necessary
Platform will not lower
No electrical signal being sent to lift down control
valve cartridge
Refer to the electrical schematic and/or electrical
system troubleshooting chart
Lift down control cartridge not functioning prop-
erly
Repair or replace lift down control cartridge
Lift cylinder not functioning properly
Repair or replace lift cylinder
Summary of Contents for 3369electric
Page 1: ...Service and Maintenance Manual ANSI Models 3369electric 3969electric 3120768 March 10 2004...
Page 2: ......
Page 11: ...SECTION 1 SPECIFICATIONS 3120768 JLG Sizzor 1 5 Figure 1 2 Serial Number Location...
Page 12: ...SECTION 1 SPECIFICATIONS 1 6 JLG Sizzor 3120768 Figure 1 3 Torque Chart...
Page 30: ...SECTION 2 PROCEDURES 2 18 JLG Sizzor 3120768 This page intentionally left blank...
Page 39: ...SECTION 3 TROUBLESHOOTING 3120768 JLGSizzor 3 9 Figure 3 1 Hydraulic Schematic...
Page 44: ...SECTION 3 TROUBLESHOOTING 3 14 JLG Sizzor 3120768 This page intentionally left blank...
Page 45: ......