SECTION 2 - PROCEDURES
2-12
– JLG Sizzor–
3120768
2.16 DRIVE TORQUE HUB
Disassembly
1.
Loosen all cover bolts (28 & 29) and drain oil from
unit.
2.
Remove the cover bolts (28 & 29) and lift off input
cover. Remove and discard o-ring from counterbore
of input cover.
3.
Remove sun gear and thrust washer.
4.
Lift out the carrier and thrust washer.
5.
Remove input spacer.
6.
Lift out internal gear and thrust washer.
7.
While wearing eye protection,
remove the retaining
ring from the output shaft and discard.
8.
Remove thrust washer from the output shaft.
9.
The output shaft may now be pressed out of the
housing.
10.
The bearing cups will remain in hub as will the inner
bearing cone. The outer bearing cone will remain on
the output shaft. The lip seal will be automatically
removed during this procedure.
NOTE:
If bearing replacement is necessary, the bearing
cups can be removed with a slide hammer puller or
driven out with a punch.
11.
To remove the cluster gears from the carrier, drive
the roll pin into the planet shaft. The planet shaft
may now be tapped out of the carrier. After planet
shaft has been removed, the roll pin can be driven
out.
Figure 2-13. Pressure Setting Procedures
Summary of Contents for 3369electric
Page 1: ...Service and Maintenance Manual ANSI Models 3369electric 3969electric 3120768 March 10 2004...
Page 2: ......
Page 11: ...SECTION 1 SPECIFICATIONS 3120768 JLG Sizzor 1 5 Figure 1 2 Serial Number Location...
Page 12: ...SECTION 1 SPECIFICATIONS 1 6 JLG Sizzor 3120768 Figure 1 3 Torque Chart...
Page 30: ...SECTION 2 PROCEDURES 2 18 JLG Sizzor 3120768 This page intentionally left blank...
Page 39: ...SECTION 3 TROUBLESHOOTING 3120768 JLGSizzor 3 9 Figure 3 1 Hydraulic Schematic...
Page 44: ...SECTION 3 TROUBLESHOOTING 3 14 JLG Sizzor 3120768 This page intentionally left blank...
Page 45: ......