SECTION 3 - TROUBLESHOOTING
3-8
– JLG Sizzor –
3120768
Table 3-5. Flash Code Troubleshooting Messages
CODE
MESSAGE
REMEDY
1 Flash
Internal fault
Replace MOS90
2 Flashes*
Check enable wiring
Check for correct start up sequence
Check that both directions are not selected
Retry
Retry
Select only one direction
3 Flashes
Check power and control wiring for shorts
Replace controller
Rectify
4Flashes
Check direction contactor tips
Check power wiring for shorts
Check motor for armature to field shorts
Check for shorts to frame and battery leakage
Replace controller
Free/change tips
Rectify
Rectify
Rectify
5 Flashes
Check contactor tips
Check contactor for mechanical operation and coil
check power and control wiring
Check motor
Replace controller
Repair/replace
Repair/replace
Rectify
Rectify
6 Flashes
Check operation of hand controller with Test Sequence
Check pot operation with voltmeter for voltage at minimum
setting
Replace controller
Rectify/replace
Adjust as necessary or replace
7 Flashes
Check battery voltage with voltmeter
Check power connections, fuses, etc.
Check for battery leakage to frame
Replace controller
Change/charge battery
Repair or replace
Rectify
8 Flashes
Check current draw
Check mounting and heat sinking of controller
Rectify
Rectify
10 Flashes
Check tachometer wiring
Check speed tachometer
Replace tachometer
Repair
Rectify
11 Flashes
Recycle emergency stop switch
Check pin voltage
Replace tachometer PC board
NOTE:
If the machine is operated at a very slow speed or stalled when climbing a grade of 20% or greater, a 10 flash fault will
occur. recycle the emergency stop switch to recover.
NOTE:
All flash codes must be checked with unit switched to platform control
* If speed switch is turned 25% - 50% toward full speed, Sevcon controller will give a 2 flash fault indicating a procedure
fault. If, while 2 flash fault is being indicated, the speed control knob is turned to less then 25% the 2 flash fault will stop
and LED will come on steady, indicating controller operational.
Summary of Contents for 3369electric
Page 1: ...Service and Maintenance Manual ANSI Models 3369electric 3969electric 3120768 March 10 2004...
Page 2: ......
Page 11: ...SECTION 1 SPECIFICATIONS 3120768 JLG Sizzor 1 5 Figure 1 2 Serial Number Location...
Page 12: ...SECTION 1 SPECIFICATIONS 1 6 JLG Sizzor 3120768 Figure 1 3 Torque Chart...
Page 30: ...SECTION 2 PROCEDURES 2 18 JLG Sizzor 3120768 This page intentionally left blank...
Page 39: ...SECTION 3 TROUBLESHOOTING 3120768 JLGSizzor 3 9 Figure 3 1 Hydraulic Schematic...
Page 44: ...SECTION 3 TROUBLESHOOTING 3 14 JLG Sizzor 3120768 This page intentionally left blank...