SECTION 3 - TROUBLESHOOTING
3120768
– JLGSizzor –
3-5
STEER SYSTEM
No response to control
Enable switch not activated
Activate enable switch
Function not activated within 3 seconds after
Enable switch was depressed
Reactivate enable switch
Enable switch not functioning properly
Replace enable switch circuit card
Hydraulic system low
Replenish oil as necessary
Damaged wiring on control switch or solenoid
valve
Repair or replace wiring as necessary
Control switch not functioning properly
Replace switch
Resrticted or broken hydraulic line on steer valve
or hydraulic pump
Clean repair or replace hydraulic line
Control valve not functioning properly
Repair or replace control valve
Steer cylinder not functioning properly
Repair or replace steer cylinder
Machine hard to steer or steering erratic
Hydraulic system oil low
Replenish oil as necessary
Restricted hydraulic line or fitting
Clean repair or replace hydraulic line or fitting
Bent steering linkage
Repair or replace steering linkage as required
Hydraulic pump not functioning properly
Repair or replace hydraulic pump
Steer cylinder not functioning properly
Repair or replace steer cylinder
Steering inoperative
Wiring damaged on control switch or solenoid
valve
Repair or replace wiring
Solenoid valve not functioning properly
Repair or replace solenoid valve
Steer control switch not functioning properly
Replace steer control switch
Steer cylinder not functioning properly
Repair or replace steer cylinder
Machine will not steer left or right
Enable switch not activated
Activate enable switch
Function not activated within 3 seconds after
enable switch was depressed
Reactivate enable switch
Enable switch not functioning properly
Replace enable switch circuit card
Wiring on steer control switch damaged
Repair or replace wiring as necessary
Wiring on steer solenoid valve damaged
Repair or replace wiring as necessary
Steer solenoid coil damaged
Replace coil
Bent steer cylinder rod
Repair or replace cylinder
Damaged steer linkage
Repair or replace steer linkage
Table 3-2. Chassis Troubleshooting
TROUBLE
PROBABLE CAUSE
REMEDY
Summary of Contents for 3369electric
Page 1: ...Service and Maintenance Manual ANSI Models 3369electric 3969electric 3120768 March 10 2004...
Page 2: ......
Page 11: ...SECTION 1 SPECIFICATIONS 3120768 JLG Sizzor 1 5 Figure 1 2 Serial Number Location...
Page 12: ...SECTION 1 SPECIFICATIONS 1 6 JLG Sizzor 3120768 Figure 1 3 Torque Chart...
Page 30: ...SECTION 2 PROCEDURES 2 18 JLG Sizzor 3120768 This page intentionally left blank...
Page 39: ...SECTION 3 TROUBLESHOOTING 3120768 JLGSizzor 3 9 Figure 3 1 Hydraulic Schematic...
Page 44: ...SECTION 3 TROUBLESHOOTING 3 14 JLG Sizzor 3120768 This page intentionally left blank...
Page 45: ......