24
JLA Limited
113538 - 7
“CAUTION: Label all wires prior to disconnection
when servicing controls. Wiring errors can cause
improper operation.”
«ATTENTION: Lor des opérations d’entretien des
commandes étiqueter tous fils avant de les
déconnecter. Toute erreur de câblage peut étre une
source de danger et de panne.»
4.
Break union connection (nut) between the external shutoff
and the gas valve.
5.
Loosen and remove screws from the brackets that are
holding the gas valve/manifold assembly to the mounting
plate. Remove the gas valve/manifold assembly from
the dryer.
6.
Unscrew main burner orifice from the manifold and replace
with the L.P. orifice provided.
IMPORTANT:
Use extreme care when removing and
replacing the orifice. The orifice is made of brass, which is
easily damaged.
7.
To convert the gas valve for use with L.P. gas, refer to the
instructions included in kit envelope (#92-0737 or
#92-0659) supplied.
8.
Reverse procedure for reinstalling the gas valve/manifold
assembly to the dryer.
9.
Affix new rating plate that came with the conversion kit
(P/N 114126).
10. Open all shutoff valves, reconnect electrical power to the
dryer, and test for leaks.
11. Open all shutoff valves (closed in Step #2), reconnect
electrical power to the dryer, and test for leaks.
IMPORTANT:
Never test for leaks with an open flame!!! Use
a soapy water solution or product intended for that purpose.
12. Verify conversion (check list)
“ITEM”
“YES”
a.
Burner orifices changed:
_____
b.
Gas valve converted:
_____
c.
Wiring reconnected to gas valve,
and wiring connections verified:
_____
d.
Labels provided affixed to gas valve,
and rating plate changed:
_____
e.
Test for gas leaks:
_____
f.
Manifold pressure tested and
confirmed to be a consistent
10.5 in WC (26.2 mbar):
_____
g.
Operate the dryer through one complete
cycle to ensure proper operation.
_____
IMPORTANT:
Conversion must be performed by competent
technicians in accordance with local and state codes.
Improper assembly or adjustments can cause hazardous
conditions.
A plugged tap, accessible for a pressure gauge connection,
must be installed in the main gas supply line immediately
upstream of the dryers.
IMPORTANT:
Pipe joint compounds that resist the action of
natural, L.P., and butane gases must be used.
Test all connections for leaks by brushing on a soapy water
solution (liquid detergent works well).
!
WARNING
Never test for leaks with a flame!!!
Converting from One Family
of Gas to Another ______________________
!
WARNING
This appliance must only be operated with the gas
type indicated on the dryer’s rating plate. If the
appliance is converted (gas type changed), a new
rating plate
must
be obtained from JLA Limited
(dryer’s serial number is required to purchase a
conversion kit).
IMPORTANT:
Any burner changes or conversions must be
made by a qualified professional.
The dryers manufactured for Belgium, Luxemburg, Greece,
Estonia, Slovak Republic, Iceland, Malta, Poland and
Cyprus cannot be converted from one family of gas to
another.
Conversion from Natural Gas
to Propane or Butane Gas
The following conversion allows the dryer to be operated with
either propane, butane, or LPG. The use of gas valve kit (P/N
140411) disables the internal regulator of the gas valve.
Therefore, the gas supply is ungoverned and an external
regulator must be provided at the source of the supply
(example L.P. tank) or the gas supply line to the dryer. The
type of L.P. kit supplied will depend on the country the dryer is
installed in.
Parts Required for Conversion:
Description
P/N
Qty
Unregulated Gas Conversion Kit
**
140411
1
OR
Regulated L.P. Gas Conversion Kit
***
140413
1
Burner Orifice (Injector)
*
1
Rating Plate
114126
1
*
Refer to page 23 for orifice (injector) size.
**
Required for unregulated propane or butane only.
***
Required for regulated LPG or propane only.
Instructions
1.
Discontinue electrical power to the dryer.
2.
Close all shutoff valves in the dryer gas supply line.
3.
Disconnect gas valve wiring.